7 / 27
3.2 Wiring mode
The junction box of AIKO ABC photovoltaic module is located in the middle. Please refer to the
following table for the series connection mode of various modules.
3.3 General safety
The design of AIKO PV module complies with IEC-61215 and IEC-61730 international
standards. The application level is class A. the module can be used for systems with DC 50V or
above 240W that the public may contact. The safety level of the module is class II and the fire
protection level is class C.
No matter whether the PV module is connected to the system or not, appropriate protective
measures shall be taken when contacting the module, such as insulating tools, safety helmets,
insulating gloves, safety belts and safety insulating shoes. When you need to install, ground, wire
and clean modules, please be sure to use appropriate electrical safety protection tools.
Under the sunlight, whether the module is connected with the electrical system or not, it can