Page 41
IAC
<CPD> Sets the main display to ac Amps and optionally sets the range; if no range
is specified the display defaults to mA autorange.
The following
<CPD> can be used to set the range:
<1MA>,<100MA>,<1000MA>,<10A>
IACDC
<CPD> Sets the main display to ac+dc Amps and optionally sets the range; if no
range is specified the display defaults to mA autorange.
The following
<CPD> can be used to set the range:
<1MA>,<100MA>,<1000MA>,<10A>
OHMS
<CPD> Sets the main display to two wire Ohms and optionally sets the range; if no
range is specified the display defaults to autorange.
The following
<CPD> can be used to set the range:
<100>,<1000>,<10K>,<100K>,<1000K>,<10M>
2WOHMS
<CPD>
Sets the main display to two wire Ohms and optionally sets the range; if no
range is specified the display defaults to autorange.
The following
<CPD> can be used to set the range:
<100>,<1000>,<10K>,<100K>,<1000K>,<10M>
4WOHMS
<CPD>
Sets the main display to four wire Ohms and optionally sets the range; if no
range is specified the display defaults to autorange.
The following
<CPD> can be used to set the range:
<100>,<1000>,<10K>,<100K>,<1000K>,<10M>
CONT Sets the main display to continuity test.
DIODE Sets the main display to diode test.
TEMPC
<CPD> Sets the main display to Celsius temperature measurement and optionally
sets the RTD probe type; if no probe is specified the existing probe is used.
The following
<CPD> can be used to set the RTD probe type:
<PT100>,<PT1000>
TEMPF
<CPD> Sets the main display to Fahrenheit temperature measurement and
optionally sets the RTD probe type; if no probe is specified the existing
probe is used.
The following
<CPD> can be used to set the RTD probe type:
<PT100>,<PT1000>
CAP
<CPD> Sets the main display to Capacitance and optionally sets the range; if no
range is specified the display defaults to autorange.
The following
<CPD> can be used to set the range:
<10NF>,<100NF>,<1UF>,<10UF>,<100UF>
FREQ
<CPD> Sets the main display to Frequency and optionally sets the range; if no
range is specified the display defaults to autorange.
The following
<CPD> can be used to set the range:
<100HZ>,<1000HZ>,<10KHZ>,<100KHZ>
AUTO Sets the main display to autorange, except for Continuity or Diode check.
MAN Sets the main display to manual, i.e. the current range is ‘locked’.