- 13 -
How to Install
■ IXG-MK
● Mounting the station on a wall
Back wiring
Surface wiring
• If the accessory screws are unusable for plaster board or a concrete wall, etc., please use a product such as an anchor 
or concrete plug (not included).
2
3
1
4
4
Attach the station to the 
mounting bracket.
Attach the 
handset.
Cat-5e/6 cable
3-gang box
Low-voltage 
lines
Low-voltage lines
Mounting bracket 
(attached to the 
back of the station)
Mounting-bracket screws 
(included) × 4
Option connector (included)
Station
※Insert a microSD card into the microSD card 
slot if needed.
Connect the option connector (included) and the low-voltage 
lines using crimping method, then connect the option connector, 
the low-voltage lines and Cat-5e/6 cable.
Attach the mounting 
bracket.
① Insert the 
connector into 
the station until 
it clicks.
② Set the 
handset on the 
station.
Recommended Mounting 
height (center of gang 
box) 1,500mm (4' 11'')
※
Wire mold
(Please prepare separately)
Please decide the size of the wire mold 
according to the wiring cables to accommodate.
92mm (3-5/8'')
83.5mm
(3-5/16'')
Mounting bracket
(attached to the back 
of the station)
Wall-mounting wood screws 
(included) x 4
Station
Connect the option 
connector 
(included), the low-
voltage lines, and 
Cat-5e/6 cable to 
the station, and 
position them as 
shown.
Wire mold
80mm (3-1/8'') 
or less
Use a covering duct for Cat- 
5e/6 cable and low-voltage 
lines, and leave a space 
(exposed portion) of no 
more than 80mm (3-1/8'') 
between the station and the 
covering duct.
Recommended 
Mounting height 
(center of mounting 
bracket) 1,500mm (4' 
11'')