11
The IXG Support Tool has a collection of optional features accessed by changing
the top menu option View from the default Basic to Advanced.
Advanced Settings
Option Input/Relay Output Settings - Option Input
Called Stations - Called Stations (Door/Sub Stations)
When an additional call button is being used with a door station, it uses an option input on that door station
to initiate the call. This option input call can be congured to operate dierently from the door station's
normal call button, and can be enabled when the door station is initially congured or after.
When with Emergency Button is checked, option inputs 1 and 6 are automatically congured to place calls. To manually
congure this, expand Option Input/Relay Output Settings and select Option Input. Choose the Option Input to set in
the Display drop-down, then set the Function to Call for the door station. Click
Save
to save the congured settings.
By default the option input call will call to the same location as the normal call button. If this needs to be changed, expand
Called Stations and select Called Stations (Door/Sub Stations), then select a dierent group in the Display settings drop-
down and add a U to the master stations and apps that will be called. Click
Save
to save the congured settings.
Site Settings - Unit/Station
To add a door station with option inputs already enabled, expand Site Settings and select Unit/Station.
Open Select Station for the door station (as detailed on page 3) and check with Emergency Button
before clicking on the appropriate door station button. Click
Save
to save the congured settings.
Option Input Calling
Upload Settings to Stations
The nal step is to upload these setting changes to the IXG stations. To upload the settings to each station,
select Connection on the top menu and click Upload Settings. Find more information on page 8.
For any other door stations besides
IX-DV, DVF or IX-SSA, the Option
Input will be enabled manually.
The red button on the IX-DVF-RA/2RA
and IX-SSA-RA/2RA stations uses
Option Input 6 and type set to Break.
Called Stations - Call Origination
To assign a new call group to the option input, expand Called Stations and select Call Origination.
Use the Display settings drop-down to select the Option Input, then set the Standard Mode Settings
Call Destination and priority level. Click
Save
to save the congured settings.