- REFER TO INSTALLATION MANUAL INSIDE LEM-1DL BOX FOR STANDARD
INSTALLATION INFORMATION -
Single Master Station with Door Release
The LEM-1DL master station provides communication to and from a door station, and has a separate
but
ton for door release. This supplemental instruction manual addresses many of the additional functions
and
modifications for the LEM-1DL system, including installation and troubleshooting information.
MASTER STATION:
LEM-1DL: 1-call master station with "Normally Open" door release button
DOOR STATIONS: (Note: Door stations are weather resistant, made for outdoor use)
LE-D: Surface mount, plastic door station (included with LEM-1DLS)
LE-DA: Flush mount in 2-gang box, stainless steel cover
LS-NVP/C: Vandal resistant flush mount in 3-gang box, white powder-coat finish
LE-SS: Vandal resistant flush mount sub in 2-gang box, stainless steel
LE-SSR: Vandal resistant, red mushroom button, flush mount in 2-gang box, stainless steel
LE-SS-1G: Vandal resistant flush mount sub in 1-gang box, stainless steel
OPTIONAL COMPONENTS & ACCESSORIES:
RY-AC/A: External signaling relay (Requires 12VDC power supply)
DAK-2S: Dual master adaptor kit
(1 per 2 master stations. Use 2 DAK-2S for up to 4 total master stations)
SBX-NVP: Surface mount box for LS-NVP/B
SBX-2G: Surface mount box for LE-SS, LE-SSR, LE-DA
SBX-1G-SS: Surface mount box for LE-SS-1G
EL-9S: Door strike (for interior wood frame doors only)
PT-1210N: AC 12V Transformer (used for door strike and for each master station)
PS-1225UL: 12V DC Power Supply, 2.5A, UL Listed
822202: 2 conductor, 22AWG, Shielded wire
(Available in 500' and 1000' boxes)
Install two separate runs of this cable, one for the intercom and one for the door
release.
2 cond. shielded for intercom
DAK-2S
(2
component modules per kit)
LE-
DA
LE-SS
LEM-1DL
LE-D
LS-NVP/
C
LEM-1DL
PT-
1210N
Separate 2 conductor for door strike
LEM-1DLS Set contains:
1 LEM-1DL, 1 LE-D, 1 PT-1210N.
Door
strike not included.
DOOR RELEA
SE WIRES MUST BE IN A SEPARATELY JACKETED CABLE FROM THE INTERCOM WIRING.
EL-9S, not included with the LEM-1DLS set.
LE-D
LEM-1DL Supplement
Pg.
1
#90111 0207

Other manuals for Aiphone LEM-1DL

Questions and Answers

  • M
    miranda48Aug 18, 2025
    How to fix AC noise when listening to the door station on Aiphone Intercom System?
    • C
      Christopher BrownAug 18, 2025
      To eliminate AC noise when listening to the door station on your Aiphone Intercom System, make sure the intercom wire is at least 20" away from any AC electrical wire, or crossed at 90 degrees. The intercom wire should be shielded, with the drain wire connected to an earth ground at the master end.
  • T
    Troy RogersAug 20, 2025
    How to eliminate AC noise when talking to the door station on Aiphone Intercom System?
    • M
      Michael SilvaAug 21, 2025
      To resolve AC noise when talking to the door station using your Aiphone Intercom System, ensure that power wires coming from the PT-1210N are not run in the same jacketed cable with the communication wires run to the door.
  • H
    Heather BrownAug 23, 2025
    Why is there feedback when pressing the talk button on my Aiphone LEM-1DL Intercom System?
    • J
      Jennifer MartinezAug 23, 2025
      If you experience feedback when pressing the talk button in a dual master Aiphone Intercom System, it might be because one power supply is used for both masters. Ensure that each master has its own power supply, using any power supply with output between 12-16V AC or 12-24V DC. Aiphone recommends the PT-1210N.
  • E
    earlmorrisonAug 26, 2025
    What to do if Aiphone LEM-1DL has no call tone, no communication, and chirps when volume is high?
    • S
      slopezAug 26, 2025
      If you're not getting a call tone or communication and hear a chirping sound when the volume is turned up on your Aiphone Intercom System, the voltage on the LEM-1DL might be incorrect. Check the power supply. If it's model SKK-620, replace it with model PT-1210N. Verify that the voltage on the +/- terminals of the LEM-1DL is between 12-16V AC or 12-24V DC.
  • J
    Jacob GarciaAug 27, 2025
    Why is call tone heard at second master when pushing talk switch on Aiphone LEM-1DL?
    • T
      Tanya NielsenAug 27, 2025
      If you hear the call tone at the second master when pushing the talk switch on one master in your dual master Aiphone Intercom System, you might be missing a DAK-2S dual master adaptor kit. Install one component module from DAK-2S at each master.
  • P
    parkertraceyAug 30, 2025
    How to fix no call tone from door to master station on Aiphone LEM-1DL?
    • R
      Robert ShawAug 30, 2025
      If you are not getting a call tone from the door to the master station on your Aiphone Intercom System: * Check if the OFF button on the master is pressed. If it is, press it to deactivate. * Also, ensure the E/- jumper is attached to the E/- terminals on the door station. The wire from E/- should connect to E of the master.
  • C
    chadwebbSep 1, 2025
    What to do if there is no communication from door station on Aiphone LEM-1DL?
    • S
      Shannon BartonSep 1, 2025
      If you have no communication from the door station on your Aiphone Intercom System, ensure that the jumper at the door station is attached between the E and - terminals.
  • C
    Christopher LuceroSep 3, 2025
    Why does external device activate when talk button is pressed on Aiphone LEM-1DL Intercom System?
    • N
      nicolas33Sep 3, 2025
      If the external device is activated every time the TALK button is pressed in a system with RY-AC and an external signaling device connected to your Aiphone Intercom System, ensure the DAK-2S component module is installed correctly. The bare wire should be under the 1 terminal, and the WHITE wire of the RY-AC spliced to the colored wire.
  • J
    Justin CollinsSep 6, 2025
    Why does feedback occur when pressing the talk button in a dual master Aiphone LEM-1DL Intercom System?
    • R
      Richard VillanuevaSep 6, 2025
      To eliminate feedback in a dual master Aiphone Intercom System when pressing the talk button, make sure each master station has its own power supply. Use a power supply with an output between 12-16V AC or 12-24V DC. Aiphone recommends the PT-1210N.
  • C
    Christine LopezSep 8, 2025
    How to stop AC noise when talking to the door station on Aiphone LEM-1DL Intercom System?
    • M
      Mrs. Jenna JohnsonSep 8, 2025
      To address AC noise when talking to the door station with your Aiphone Intercom System, ensure that the power wires coming from the PT-1210N are not run in the same jacket cable as the communication wires to the door.

Summary

LEM-1 DL Master Station

Master Station Description

1-call master station with a "Normally Open" door release button for communication.

Door Station Options

Weather-Resistant Door Station Types

Describes various vandal-resistant and flush/surface mount door stations for outdoor use.

Optional Components and Accessories

System Expansion and Power Components

Lists components for system expansion, signaling, door release, and power supplies.

Dual Master System Installation

Dual Master Wiring Diagram

Illustrates wiring for a dual master LEM-1DL system using the DAK-2S adaptor.

Dual Master Operation Notes

Details usage rules, including single master operation and feedback prevention.

Dual Master Installation Guidelines

Provides essential steps for installing dual master stations, including wiring and power.

Multiple Master Station System

4 Master Station Wiring Example

Shows the wiring configuration for four LEM-1DL master stations with one door station.

External Signaling and Magnetic Locks

External Signaling Wiring

Diagram and notes for connecting an external signaling device using the RY-AC relay.

Magnetic Lock System Configuration

Details on wiring a normally closed (N/C) relay for magnetic locks using RY-18L or RY-24L.

General Installation Tips

Wiring and Placement Recommendations

Advises on using shielded wire, separating cables, and avoiding interference sources.

Troubleshooting Guide

Common System Issues and Solutions

Addresses problems like no call tone, no communication, feedback, and AC noise.

Aiphone LEM-1DL Specifications

General IconGeneral
Product colorBlack, White
Indoor unit includedYes
Outdoor unit included-
Indoor units quantity1
Connectivity technologyWired
Indoor unit power typeAC/DC
Weight and Dimensions IconWeight and Dimensions
Depth53.9 mm
Width136.5 mm
Height179.3 mm

Related product manuals