EasyManua.ls Logo

Air King ES130D2 - User Manual

Air King ES130D2
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
f) This unit must be grounded.
g) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
h) Suitable for use with electronic speed control device.
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND
VAPORS.
WARNING: DO NOT USE IN KITCHENS.
i) Read all instructions before installing or using exhaust fan.
www.airkinglimited.com
6728039 Rev. B 3-13 1 of 12
Exhaust Fan
Models: ES80D, ES130D, ES80DG,
ES130DG, ES80DH, ES130DH, ES130D2

Questions and Answers

  • M
    martinnicholeAug 11, 2025
    What to do if my Air King ES130D2 does not operate when the switch is on?
    • R
      Rachel BaldwinAug 11, 2025
      If your Air King Fan isn't working when switched on, a common cause is a blown fuse or tripped circuit. Try replacing the fuse or resetting the circuit breaker. Also, ensure the connector plug from the motor is properly plugged in by turning off the power, removing the grill, plugging the motor into the receptacle, and then restoring power. Check that all wires are securely connected after turning off the power. If the motor has stopped working entirely, it will need to be replaced.
  • J
    jeremylarsonAug 21, 2025
    What to do if air moves slower than normal in my Air King ES130D2?
    • J
      John FullerAug 21, 2025
      If the air moves slower than normal in your Air King Fan, there may be an obstruction in the exhaust ducting. Check for obstructions, such as bird nests, in the roof or wall cap where the fan exhausts to the outside.
  • T
    Tara BoothAug 31, 2025
    Why is my Air King ES130D2 operating louder than normal?
    • J
      Jeremy ShafferAug 31, 2025
      If your Air King Fan is louder than usual, it might be due to a loose motor. Turn off the power, remove the grill, and check if all screws are fully tightened. Restore power after checking. If the fan blade is hitting the housing, call your dealer for service.

Air King ES130D2 Specifications

General IconGeneral
BrandAir King
ModelES130D2
CategoryFan
LanguageEnglish

Related product manuals