INSTALLATION INSTRUCTIONS FOR HERON Q
The HERON Q is suitable for installation in most caravans & motorhomes.
Installation in commercial and industrial vehicles and equipment should be
referred to AIRCOMMAND AUSTRALIA or agent for assessment of suitability.
The Heron System must be installed in accordance with National wiring
regulations.
The capacity of the air-conditioner to adequately cool or heat a van is dependent
on:
the size of the van or vehicle.
the thickness and quality of thermal insulation.
the expected outside or ambient conditions.
The HERON Q is recommended for vans up to 7.0 meters overall, but assumes
that all walls and ceilings are insulated with a minimum of 25mm of insulation
wool or foam. The Heron Q may be used in vans up to 9 metres provided the
insulation is a minimum 38mm thick and all windows are double insulated.
Windows should all have shades, or curtains as a minimum. If the van is to be
used mainly in extreme conditions (40°C plus) then be conservative. i.e. Ensure
the best insulation is installed, consider double glazed windows, and size the unit
down to 6m.
Figure 1
1

Other manuals for Aircommand Heron Q

Question and Answer IconNeed help?

Do you have a question about the Aircommand Heron Q and is the answer not in the manual?

Summary

INSTALLATION OF THE CONDENSER SET

PIPE INSTALLATION & CONTROL WIRING

AIR HANDLER INSTALLATION

Now Install the Air Handler

Charging the system

Method 2 (Preferred)

Details the preferred vacuum method for charging the air conditioning system.

Leak testing

Use an ELECTRONIC leak detector.

Details the use of an electronic device for leak detection.

INSTALL BITUMINOUS TAPE AROUND 9.5 FLARE NUT AT THE A;H.

Initial Run & Test

Procedures for the initial power-up and testing of the unit.

Trouble Shooting

Unit does not energize

Provides solutions for the unit failing to power on.

Compressor and Cond. Fan will not run

Addresses issues where the compressor and fan do not operate.

TROUBLE SHOOTING

Insufficient cooling

Solutions for the unit not providing adequate cooling.

Aircommand Heron Q Specifications