20
FIRST USE
1. Check if the instructions mentioned above have been executed.
2. On delivery the compressor mostly is not filled with oil. Fill about 0,25
litres compressor oil until the maximum stripe on the oil-level indicator
(13).
3. Install the air filter (1) in the cylinder head (first remove the synthetic plug).
4. Install the oil filler cap/oil-level indicator (13) on the crank case lid (first remove
the synthetic plug).
5. Avoid the use of extension cables. If you use them, unroll them completely and
use cables of sufficient capacity. Tabel for extension cables:
0 - 10 meter: 3 x 1,5 mm
2
and 10 - 25 meter: 3 x 2,5 mm
2
Switch on the compressor by means of pulling the pressure switch (4).
The compressor will now operate, unless the air receiver is still under pressure
(pressure gauge 8).
Switch the machine, during operation, exclusively off by means of pushing the
button on the automatic pressure switch (4); the pressure circuit will be vented
and the compressor can start again uncharged.
OPERATION
1. The automatically operating compressor will stop at a pressure of 8 bar (8).
When air is used again and the pressure in the tank falls to 6 bar, the
compressor will start again.
2. Most pneumatic machines are suitable for an operating pressure of about 6
bar. For some applications this pressure is even lower. To be able to set the
right pressure, the compressor is provided with a reducing valve (5). This valve
can set the pressure of the air receiver (of course never higher than the
pressure in the air receiver).
3. The setting of the reducing valve is done as follows: switch the button to set the
right pressure (to the left to lower the pressure, to the right to increase it). The
setting pressure is shown at the gauge (7).
4. Two extra plugs (9) are fitted to the tank, which can be used to get an extra
pressure connection.