7.0 POSSIBILIBIES OF FAILURE
1 Compressor does not run at starting pressure:
* blown fuse - renew the fuse
* tank at pressure - discharge
* motor broken - repair/renew
* defective pressure switch - repair/renew
2 Repeating thermal failure:
* loose wire - repair
* pressure switch does not releave - repair/renew valve
air circuit
* too low voltage - remove extension cable or use heavier
* overloading - reduce loading
3 Compressor keeps blowing off air:
* defective non-return valve - repair/renew
4 Too little air production:
* dirty air filter - clean/renew filter
* defective valves - renew
5 Leaking safety valve:
* pressure too high - set pressure switch
* defective safety valve - renew
8.0 TECHNICAL DETAILS
Type HL 310/25
Order number 36839
Number of cylinders 1
Number of stages 1
Motorpower 2 Hp/1,5 kW
Volt 230 V/50 Hz
Air tank 25 litres
Oil tank 0,25 litres
Operating pressure 6 bar
Maximum pressure 8 bar
Sound pressure level 78 dB(A)
Air intake capacity 310 l/min.
Protected with 16 amp.
Service 30%-60 min.
Weight 25 kg
Dimensions (lxwxh) (mm) 595x350x600
Modelchanges reserved.
All compressors are provided with Euro-Norm (CE-Choice)