EasyManua.ls Logo

AirSep newlife intensity - User Manual

AirSep newlife intensity
144 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
NewLife
®
Intensity F
AirSep
®
Corporation
MANUEL D’UTILISATION
GEBRAUCHSANWEISUNG
MANUAL DEL USUARIO
ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ
USER’S MANUAL
MANUALE DI UTILIZZAZIONE
HANDLEIDING
MANUAL DE UTILIZAÇÃO
HANDBOK
BRUGERVEJLEDNING
AirSep Corporation
401 Creekside Drive
Buffalo, New York 14228 USA
Tel: +1-716-691-0202
Fax: +1-716-691-4141
FR
DE
ES
GB
EL
IT
PT
NL
0459
DA
SV

Table of Contents

Other manuals for AirSep newlife intensity

Questions and Answers

  • J
    Joseph WhiteAug 13, 2025
    Why does my AirSep newlife intensity alarm sound when it's running?
    • J
      jeffrey42Aug 13, 2025
      If the AirSep Air Compressor is on, the compressor is operating, there is a flow, but the audible alarm sounds, it may be due to an internal electrical fault or a pneumatic circuit fault. Stop the device and contact your distributor.
  • M
    Matthew KellyAug 17, 2025
    What to do if AirSep newlife intensity does not operate and the alarm sounds?
    • J
      Joseph JohnsonAug 17, 2025
      If the AirSep Air Compressor doesn't operate, the 0-I button is ON, and the alarm sounds continuously, first check the power cable connection to ensure it's properly plugged in. If the issue persists, check the fuses or circuit breaker fitted on the premises and reset the circuit breaker if necessary.
  • K
    kayla99Aug 21, 2025
    Why does my AirSep newlife intensity Air Compressor stop and start again?
    • M
      Melissa WalshAug 21, 2025
      If the AirSep Air Compressor stops mid-cycle and restarts after a few minutes, it may be due to the compressor thermal safety device being tripped. Stop the device and allow it to cool down. Also, check that the patient circuit is not obstructed. If the device still doesn't start after cooling, contact your distributor.
  • C
    Christina FaulknerAug 25, 2025
    What to do if AirSep newlife intensity is running but there is no flow?
    • K
      kristensmithAug 25, 2025
      If the AirSep Air Compressor is on, the compressor is operating, but there is no flow and the alarm sounds, it could be due to a broken pneumatic connection or a compressor problem. Stop the device by pressing the 0-I button and contact your distributor.
  • R
    Richard RandallAug 28, 2025
    How to fix interrupted airflow in AirSep newlife intensity?
    • K
      Kimberly HurstAug 28, 2025
      If the oxygen-enriched air flow is interrupted at the nasal cannula outlet of your AirSep Air Compressor, check the gas administration circuit to ensure the tube is connected and the humidifier is tight.
  • T
    tanner64Sep 1, 2025
    What to do if AirSep newlife intensity Air Compressor flow is irregular?
    • S
      Scott MillerSep 1, 2025
      If the flow at the nasal cannula outlet of the AirSep Air Compressor is irregular, it indicates a pneumatic circuit problem. Contact your distributor.
  • R
    Rhonda DiazSep 4, 2025
    Why is the oxygen concentration indicator yellow on AirSep newlife intensity?
    • R
      robertcurtisSep 4, 2025
      If the oxygen concentration indicator remains lit yellow on your AirSep Air Compressor, it means the oxygen concentration is too low. Contact your distributor.
  • J
    justin37Sep 8, 2025
    What to do if alarm test doesn't work on AirSep newlife intensity?
    • P
      petersonkarenSep 9, 2025
      If the alarm test does not work on your AirSep Air Compressor, it indicates an internal electrical fault. Contact your distributor.

Summary

General Safety Guidelines

Oxygen Safety Precautions

Guidelines for handling oxygen safely, avoiding fire hazards, and ensuring proper ventilation.

Device Operation and Maintenance Safety

Instructions for safe use and maintenance, including electrical safety and prescription adherence.

Starting Up and Installation

Direct Oxygen Therapy Setup

Step-by-step instructions for setting up and operating the device for direct oxygen therapy.

Cleaning and Maintenance

Useful Information

Alarms and Safety Devices

Details on the device's audible and visual alarms, and built-in safety mechanisms.

Technical Specifications

Key technical data including dimensions, weight, noise level, and flow rates.

Troubleshooting Common Issues

Guidance on identifying and resolving common problems encountered with the device.

AirSep newlife intensity Specifications

General IconGeneral
Oxygen Concentration93% ±3%
Oxygen Purity93% ±3%
Operating Pressure9.5 PSI
Noise Level45 dB
Power Supply110-120V, 60Hz

Related product manuals