EasyManua.ls Logo

AirTech VCX 60 - Inline (Inlet) Filter; Maintenance Chart

AirTech VCX 60
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.2 Inline (Inlet) Filter
Check inline (inlet) filter on a weekly basis. The filter cartridge should be cleaned or replaced if it is dirty.
Consult Airtech for replacement elements.
Caution: Depending on the mounting position of the filter, be careful not to allow accumulated
foreign material to fall in the pump suction inlet when removing the filter cartridge. Horizontal
filter installation is recommended to prevent this.
4.3 Maintenance Chart
Weekly
Check inline inlet filter element/mesh. (this might need to be performed more often if
there are high particulates in the inlet stream)
Monthly
Check the oil level and protective mesh.
Semi-
Annually
Check fans and coupling
Annually
Check Bearings/ Shaft Seals, (this might need to be performed more often if the unit is
operating at ambient temperature that exceeds 68° F (20° C).
Every 1500
operating
hours
Check grease conditions and add additional grease if necessary, especially if the unit is
being operated at an ambient temperature that exceeds 68° F (20° C).
Every 5000
operating
hours
Check the gear oil conditions, and if necessary, change the oils.

Related product manuals