Pre-Installation Procedures

Cautions and Operating Warnings

Safety guidelines for unit operation, pressure, and environment.

Dryer Installation Guidelines

Principle of Operation

Displays and Alarms

Dew Point Controller and Display

Controls dew point, displays temp, and error codes.

Dryer Start Up Procedure

SC;CT 40-250 Initial Start Up

Steps for initial power connection and setup for specific models.

SC;CT 330 and Up Initial Start Up

Steps for initial power connection and setup for higher models.

Routine Maintenance and Service

Refrigeration Service Technician

Refrigerant and Oil Charging

Procedures for charging refrigerant and oil, and assessing charge.

Electronic Control System

Troubleshooting Control Malfunctions

Common issues with controllers and solenoids.

Miscellaneous Dryer Data

Dryer Information Charts

Model Specifications Table

Technical data including HP, FLA, Volt, Amps, Fuse, Breaker, BTU, CFM, Oil.

Electrical Control Diagrams

SC;CT 40-60 115 VAC Control Circuit

Wiring diagram for specific models and voltage.

SC;CT 80 115 VAC Control Circuit

Wiring diagram for SC/CT 80 model at 115VAC.

SC;CT 100-165 115 VAC Control Circuit

Wiring diagram for SC/CT 100-165 models at 115VAC.

SC;CT 220-250 115 VAC Control Circuit

Wiring diagram for SC/CT 220-250 models at 115VAC.

SC;CT 300-1200 115 VAC Control Circuit

Wiring diagram for SC/CT 300-1200 models at 115VAC.

SC;CT 1500 115 VAC Control Circuit

Wiring diagram for SC/CT 1500 model at 115VAC.

SC;CT 2000-2500 115 VAC Control Circuit

Wiring diagram for SC/CT 2000-2500 models at 115VAC.

SC;CT 3000 115 VAC Control Circuit

Wiring diagram for SC/CT 3000 model at 115VAC.

High Voltage Diagrams

SC;CT 220-330 High Voltage Side

High voltage wiring for 230V/1PH/60HZ models.

SC;CT 220-330 High Voltage 3 PH

High voltage wiring for 230V/460V/3PH/60HZ models.

System Operation Diagrams

Troubleshooting Diagnostics

E1: Open Dew Point Circuit

Diagnosing and resolving open circuits in the dew point sensor.

E2: Shorted Dew Point Circuit

Diagnosing and resolving short circuits in the dew point sensor.

E3: High Super Heat Shutdown

Identifying causes for high super heat shutdown.

E4: Freeze Protection Shutdown

Troubleshooting freeze protection shutdowns and unloader valve issues.

E5: High Dew Point Shutdown

Diagnosing high dew point alarms and compressor issues.

E6: Low Suction PSI Shutdown

Troubleshooting low suction pressure and related issues.

E7: High Head PSI Shutdown

Diagnosing high head pressure shutdown.

AirTek CT 330-A4 Specifications