SMART CYCLE
COLD TRAP
REFRIGERATED
AIR DRYERS
OPERATORS MANUAL:
MODELS SC/CT 40 to 3000
Service Department
1-800-451-6023
MAN-SCCT
PRICE $10.00

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the AirTek CT 165 and is the answer not in the manual?

Summary

Pre-Installation Procedures

Inspection, Handling, and Setup

Inspect dryer for damage upon arrival and note any issues on the freight bill for claims.

Safety Cautions and Operating Warnings

Lists critical safety rules for operating and maintaining the dryer unit safely.

Dryer Installation Guidelines

Electrical Connection Procedures

Instructions for safe electrical hookup, including disconnect switches and grounding.

Control Panel Displays and Alarms

Dryer Start Up Procedures (SC;CT 40-250)

Electrical and Water Connections

Steps for making electrical connections and preparing water supply.

Refrigeration Service Valve Operation

Guidance on opening and operating specific refrigeration service valves.

Initial Dryer Operation Sequence

Steps for powering on, cycling, and introducing air to the dryer.

Routine Maintenance and Service

Air Cooled Condenser Cleaning

Importance of keeping the condenser clean for optimal performance and longevity.

Refrigeration Service Technician Notes

Recharging Dryer: Refrigerant, Oil, and Dryers

Procedures and considerations for refilling refrigerant and oil.

Diagnosing Evaporator Leaks

Methods for identifying leaks between the tube and shell sides of the evaporator.

Diagnostic Codes and Troubleshooting

Diagnostic Code E1: Open Dew Point Circuit

Troubleshooting for open circuits affecting the dew point sensor.

Diagnostic Code E2: Shorted Dew Point Circuit

Troubleshooting for short circuits in the dew point sensing circuit.

Diagnostic Code E3: High Super Heat Shutdown

Identifies causes and solutions for high super heat conditions.

Diagnostic Code E4: Freeze Protection Shutdown

Addresses issues related to freezing and protection shutdowns.

Diagnostic Code E5: High Dew Point Shutdown

Troubleshooting for shutdowns due to high dew point readings.

Diagnostic Code E6: Low Suction PSI Shutdown

Troubleshooting for low suction pressure shutdowns.

Diagnostic Code E7: High Head PSI Shutdown

Troubleshooting for shutdowns caused by excessive head pressure.

Liquid Line Solenoid Malfunction

Troubleshooting for issues with the liquid line solenoid valve.

Diagnostic Code E9: Drain Shutdown

Causes and resolution for drain-related shutdowns.

Miscellaneous Dryer Data

Parts Ordering and Coalescer Replacement

AirTek CT 165 Specifications