SMART CYCLE
COLD TRAP
REFRIGERATED
AIR DRYERS
OPERATORS MANUAL:
MODELS SC/CT 40 to 3000
Service Department
1-800-451-6023
MAN-SCCT
PRICE $10.00

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the AirTek SC 165 and is the answer not in the manual?

Summary

Pre-Installation

Inspection, Handling, and Setup

Check for damage upon arrival and file claims immediately.

Cautions and Operating Warnings

Safety guidelines for operation, pressure, and environment.

Dryer Installation

Electrical Connections

Covers voltage checks, disconnects, grounding, and wiring.

Principle of Operation

Air System

Explains the path and treatment of compressed air through the dryer.

Refrigeration System

Describes the components and function of the refrigerant cycle.

Control Panel Features and Indicators

Dew Point Controller and Display

Describes the dew point display and its functions, including error codes.

Dryer Startup Procedures

SC;CT 40-250 Startup

Step-by-step guide for initial startup of specific models.

Detailed Startup Steps

Comprehensive instructions for connecting power and initiating operation.

SC;CT 330 and Up Startup

Specific startup steps for larger model series.

Routine Maintenance and Service

Refrigeration Service Technician Guide

Refrigerant Charging Procedures

Guidance on charging refrigerant, oil, and assessing charge levels.

Evaporator Leaks and Control Valves

Troubleshooting evaporator leaks and refrigerant control valves.

Miscellaneous Dryer Data

Electrical Control Circuit Diagrams

High Voltage Diagrams

System Diagrams

Diagnostic Codes and Troubleshooting

E1: Open Dew Point Circuit

Identifies and troubleshoots open circuits in the dew point sensor.

E2: Shorted Dew Point Circuit

Identifies and troubleshoots short circuits in the dew point sensor.

E3: High Super Heat Shutdown

Addresses high super heat conditions and potential causes.

E4: Freeze Protection Shutdown

Explains freeze protection shutdown and causes like unloader valve failure.

E5: High Dew Point Shutdown

Details causes for high dew point shutdown, like compressor issues.

E6: Low Suction PSI Shutdown

Explains low suction pressure shutdown and potential causes like low freon.

E7: High Head PSI Shutdown

Covers causes of high head pressure shutdown, like overload or dirty condenser.

E9: Drain Shutdown Alarm

Explains the E9 alarm for continuous drain valve operation.

Instructions for Ordering Parts

AirTek SC 165 Specifications

General IconGeneral
BrandAirTek
ModelSC 165
CategoryDryer
LanguageEnglish