Page #13 background image
2-5
PRODUCT DATA SHEET
Revision 0
Model Indoor Unit FLO 18 N
Model Outdoor Unit GC 18 N
Installation Method of Pipe Flared
Characteristics Units Cooling Only Cooling Heating
Capacity
(1)
Btu/hr 18250 18250 18420
kW 5.35 5.35 5.40
Power input
(1)
kW 1.66 1.66 1.56
EER (Cooling) or COP(Heating)
(1)
W/W 3.22 3.22 3.46
Energy efficiency class
A
AB
Power supply V/Hz/Ph 220-240V/50Hz/Single
Rated current A 7.5 7.5 7.1
Starting current A 43
Circuit breaker rating A 15
INDOOR
Fan type & quantity Cross flow*1
Fan speeds H/M/L RPM 1200/1100/1000
Air flow
(2)
H/M/L m3/hr 930/840/750
External static pressure Min-Max Pa N/A
Sound power level
(3)
H/M/L dB(A) 56-53-50
Sound pressure level
(4)
H/M/L dB(A) 43-40-37
Moisture removal l/hr 1.8
Condenstate drain tube I.D mm 16
Dimensions WxHxD mm 1060x295x210
Weight kg 14
Package dimensions WxHxD mm 1115x350x260
Packaged weight kg 17
Units per pallet units 16
Stacking height units 8
OUTDOOR
Refrigerant control Capillary tube
Compressor type,model Rotary,TOSHIBA PA200X2CS-4KU1
Fan type & quantity Propeller(direct) x 1
Fan speeds H/L RPM 815
Air flow H/L m3/hr 2480
Sound power level H/L dB(A) 68
Sound pressure level
(4)
H/L dB(A) 57
Dimensions WxHxD mm 846*302*690
Weight kg 56
Package dimensions WxHxD mm 990*430*770
Packaged weight kg 61
Units per pallet Units 9
Stacking height units 3
Refrigerant type R410A
Refrigerant chargless distance kg/m 1.54kg/7.5m
Additional charge g/m
4m≤Length≤10m 1540g 10m Length≤18m 1690g
18m Length≤25m 1900g
Connections between
units
Liquid line In.(mm) 1/4”(6.35)
Suction line In.(mm) 1/2”(12.7)
Max.tubing length m. 25
Max.height
difference
m. 15
Operation control type Remote control
Heating elements kW
Others All season kit Factory option
(1)
Rating conditions in accordance with ISO 5151, ISO 13253 (for ducted units) and EN 14511.
(2)
Airflow in ducted units; at nominal external static pressure.
(3)
Sound power in ducted units is measured at air discharge.
(4)
Sound pressure level measured at 1 meter distance from unit.

Questions and Answers: