1. Fix the Smart Bracket panel on the ceiling using bundled screws. If you use
any other attachment tools, make sure that they do not damage or deform
the attachment panel.
Use double-side adhesive tape only for temporary attachment of the detector. The tape runs dry
with time, which can cause falling, false triggering, and detector malfunction.
2. Put the detector on the attachment panel by turning it clockwise on Smart
Bracket. When the detector is fixed in Smart Bracket, it blinks with LED,
signalling that the tamper is closed.
If LED doesn’t blink after fixing in Smart Bracket, check the status of the
tamper in the Ajax app and then the fixing tightness of the panel.
If someone detaches the detector from the surface or takes it off the
attachment panel, the security system notifies you.
Do not install the detector:
1. outside the premises (outdoors);
2. nearby any metal objects or mirrors causing attenuation or screening of the
signal;
3. at any places with fast air circulation (air fans, open windows or doors);
4. closer than a meter to the cooking surface;
5. inside premises with the temperature and humidity beyond the range of
permissible limits;
6. Closer than 1 m to the hub.
Autonomous Use of the Detector
The detector can be used autonomously, without connecting to a security
system.
1. Switch on the detector by pressing the on/off button for 3 seconds (the logo
will light up green for 1 second) and conduct the smoke test.
2. Select the optimal location of the detector following the recommendations
in the second part of the section selecting the location of this manual.
3. Install the detector as described in the section Installation procedure.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AJAX Fire Protect and is the answer not in the manual?

AJAX Fire Protect Specifications

General IconGeneral
Smoke-sensitive elementPhotoelectric sensor
Temperature sensitive elementThermocouple
Tamper protectionYes
CompatibilityOperates independently or with Hub, Hub Plus, Hub 2, ReX, ocBridge Plus, uartBridge
Sound notification volume85 dB at a distance of 3 m
Alarm threshold at the temperature+59°С ±2°С
Operating temperature rangeFrom 0°С to +65°С
Operating humidityUp to 80%
Frequency band868.0 – 868.6 MHz or 868.7 – 869.2 MHz depending on the region of sale
Radio signal modulationGFSK
Radio signal rangeUp to 1, 300 m (any obstacles absent)
Maximum RF output powerUp to 20 mW
Power supply2 × CR2 (main batteries), CR2032 (backup battery), 3 V
Battery lifeUp to 4 years
Weight and Dimensions IconWeight and Dimensions
Overall dimensions132 × 132 × 31 mm
Weight220 g