Installation (Cont.)
Fitting guidelines
The cooker is manufactured to work with three-phase alternating current
(400V 3N~50Hz). The voltage rating of the cooker heating elements is 220-
240V. Adapting the cooker to operate with one-phase current is possible
by appropriate bridging in the connection box according to the connection
diagram (Fig. 16). The connection diagram is also found on the cover of
the connection box. Remember that the connection wire should match the
connection type and the power rating of the cooker.
The connection cable must be secured in a strain-relief clamp.
CAUTION!
Remember to connect the safety circuit to the connection box terminal
marked with
ELECTRICAL CONNECTION
Caution!
All electrical work should be carried out by a suitably qualified and authorized electrician.
No
alterations or willful changes in the electricity supply should be carried out.
Fitting guidelines
The cooker is manufactured to work with three-phase alternating current (380-415V 3N~50
Hz)
. The voltage rating of the cooker heating elements is 220-240V. Adapting the cooker
t
o operate with one phase current is possible by appropriate bridging in the connection box -
b
ox according to the connection diagram below. The connection diagram is also found on t
he cover of the connection box. Remember that the connection wire should match the
c
onnection type andthe power rating of the cooker.
CONNECTION DIAGRAM
C
aution! Voltage of heating elements 220-240V
C
aution! In the event of any connection the safety
Wir
e must be connected to the E terminal.
R
ecommended
t
ype of
c
onnection
le
ad
1
For 220-240V earthed one-phase
connection, bridges connect 1-2-3
terminals and 4-5 terminals, safety
wir
e to
.
L1
N
E
H0
5VV-F3G4
2
For 380-415/220-240V earthed two-
p
hase connection, bridges connect
2-3 terminals and 4-5 terminals, the
s
afety wire to
L1L1
E
NN
L2
L2
H0
5VV-F4G2,5
3
For 380-415/220-240V earthed three--
p
hase connection, bridges connect 4-5
terminals, phases in succession 1,2
a
nd 3, earth to 4-5, the safety wire to
.
NN
E
L1
L1
L2 L3
H0
5VV-F5G1,5
L1
=R, L2=s, L3=T, N=earth terminal, E=safety wire terminal
1
2 3
4
The connection cable must be secured in a strain-relief clamp.
.
Before connecting the cooker to the power
s
upply it is important to read the
in
formation
c
onnection diagram.
Caution!
Remember to connect the safety circuit to
t
he connection box terminal marked with
.
The fixing line connected must be equipped with the all-pole disconnection device
p
rovided by breakaway the contact under overvoltage category III according to the
t
he wiring rules.
on the data plate and the
23
. Before connecting the oven to the power supply make sure
to read the information on the data plate and the connection diagram.
Fig. 16
Earth
Earth
E=Earth terminal, N=Neutral wire terminal
Earth
and 3, Neutral
connect 4-5
contacts