Loading...
NOTES:
20
1,
.
Because
each
of
these
adjustments
are
vital
to
perfect
Dolby
NR
circuit
operation,
be
sure
that
they
un
sb
Output
Level
Control
should
be
at
maximum.
are
carried
out
with
as
little
error
as
possible.
.
Except
for
Steps
6,
7
and
9
set
tape
selector
to
Low
Noise
position.
.
Set
Dolby
NR
switch
to
OFF
position.
.
Use
the
following
cassette
measuring
tapes:
LN
Tape:
Fuji
FL
C-60
LH
Tape:
Maxell
UD
C-60
CrO,
Tape:
TDK
SA
C-60
Fe-Cr
Tape:
SONY
Duad
C-60
.
Stop
recording
bias
oscillator
while
making
Rec
Peaking
Adjustment
(Refer
to
Fig.
16).
.
If
a
flat
characteristic
cannot
be
obtained
from
1,000
Hz
to
10,000
Hz
at
CrO,,
or
Fe-Cr
positions,
fine
adjust
at
VR6
(CrO,),
or
VR5
(Fe-Cr)
respectively.
.
If
it
does
not
comply
with
the
specifications,
repeat
Steps
5
to
8
and
re-adjust.
.
Adjust
the
oscillators
frequency
to
give
a
frequency
counter
reading
of
19.00
kHz.
.
Unless
the
core
is
moved
intentionally
this
adjustment
is
not
necessary.