- 6 -
Measurement Specifications Measurement Condition/Method/Remarks Measurement
Description Test Input Input Signal Output Vol. Method/Remarks
Point Selector Freq. Level Level
Frequency - 5.0 dB ± 3.0dB SP AUX 10Hz Adjust 0dBs MAX Measure the level
Response - 4.0 dB ± 3.0dB OUT
100kHz difference from 1kHz
output
Super Bass + 10dB ± 3.0dB SP AUX 70Hz Adjust 0dBs 30 Measure the level
OUT difference ( S BASS
ON)-(S BASS OFF)
at 1kHz Volume
Level 30 Position
Loudness Low + 6.0 dB ± 3.0dB SP AUX
100Hz Adjust 0dBs 30 Volume Level 30
Equalizer - 10.0 dB ± 3.0dB OUT Position
High + 5.0 dB ± 3.0dB 10kHz
- 7.0 dB ± 3.0dB
NO. Designation Requirement Reference Model Remark
1 Standard signal EXT. MOD. Input LEADER 3216 1 set
Generator Modulation: AM 0-60%
FM 0-99.9KHz
Frequency: 0.1-140MHz
Level: -20-120dBu
Output: 1-50W
2 AC voltmeter Inter Resistance 1M-10MW KENWOOD V7-171 2 set
3 Automatic VP7702C 1 set
Distortion Meter
4 CD Player NF3346A 1 set
Evaluation Filter
5 Multiplex Signal KIKU SUI 3400S 1 set
Generator
6 Oscilloscope Max Frequency of input signal; KENWOOD CO-1305 2 set
5MHz
7 Oscillator Frequency of output signal; KENWOOD AG-203A 2 set
20Hz-20kHz
8 Test Loop Resistance: 50 LEADER LPA-070 1 set
Frequency: 100KHz~30MHz
9 WOW FLUTTER MEGURO 1 set
METER MK-668G
III. Level List of Equipments & Instruments Required for Production