ADC-ACC1-17 Installation Guide | 11
VO (12 Vdc)
GND
DAT
CLK
1
OSDP PROTOCOL DEVICE
9600 BAUD
ADDRESS 0
1
TB2
VO (12V DC)
GND
LED
BZR
CLK/D1
DAT/D0
TB3
1
BZR
DAT/D0
CLK/D1
LED
SECOND READER PORT
1
TB4
GND
VIN
GND
VO
BZR
1
GND
GND
VIN
VO
DAT/D0
CLK/D1
1
LED
LED
BZR
FIRST READER PORT
1
BZR
VO
DAT/D0
CLK/D1
LED
GND
VIN
GND
TB4
TB3
1
VO (12 Vdc)
CLK
LED
BZR
GND
DAT
TB2
1
REMOTE SERIAL I/O MODULEREMOTE SERIAL I/O MODULE
MR16in
MR16out
FOR EXAMPLE:
MRDT
MR50
MR52
GND
GND
12 Vdc
TR+
TR-
MRDT
FOR EXAMPLE:
MR50
MR16out
MR16in
MR52
GND
TR+
12 Vdc
GND
TR-
OSDP PROTOCOL DEVICE
ADDRESS 1
9600 BAUD
TR+
TR-
FIRST READER PORT
REFER TO THE APPROPRIATE REMOTE SERIAL I/O DEVICE INSTALLATION MANUAL FOR
ADDRESS AND BAUD RATE SETTINGS. DO NOT TERMINATE ANY OF THE DEVICES ON
THE RS-485 MULTI-DROP COMMUNICATION BUS. EACH REMOTE SERIAL I/O DEVICE
MUST BE CONFIGURED WITH AN UNIQUE COMMUNICATION ADDRESS. A MAXIMUM OF
EIGHT REMOTE SERIAL I/O DEVICES MAY BE CONNECTED TO READER PORT 1.
REFER TO THE APPROPRIATE REMOTE SERIAL I/O DEVICE INSTALLATION MANUAL FOR
ADDRESS AND BAUD RATE SETTINGS. DO NOT TERMINATE ANY OF THE DEVICES ON
THE RS-485 MULTI-DROP COMMUNICATION BUS. EACH OSDP DEVICE MUST BE
CONFIGURED WITH AN UNIQUE COMMUNICATION ADDRESS. A MAXIMUM OF TWO OSDP
DEVICES MAY BE CONNECTED TO READER PORT 1.
(12V DC)
+12 Vdc
D1
GROUND
DO (GREEN LED)
F/2F Reader
1
TB2
VO (12 Vdc)
GND
LED
BZR
CLK/D1
DAT/D0
+12 Vdc
D1
GROUND
DO (GREEN LED)
F/2F Reader
NORMALLY CLOSED CONTACT *
DOOR MONITOR SWITCH
REQUEST TO EXIT SWITCH
NORMALLY OPEN CONTACT *
1K,1%
1K,1%
1K,1%
1K,1%
1
VO (12 Vdc)
GND
LED
BZR
CLK/D1
DAT/D0
TB2
1
BZR
DAT/D0
CLK/D1
LED
1
GND
VIN
GND
VO
+12 Vdc
D1
GROUND
DO (GREEN LED)
F/2F Reader
1K,1%
1K,1%
1K,1%
1K,1%
TB3
1
BZR
DAT/D0
CLK/D1
LED
1
TB4
GND
VIN
GND
VO
+12 Vdc
D1
GROUND
DO (GREEN LED)
F/2F Reader
SECOND READER PORT
FIRST READER PORT
FIRST READER PORT
SECOND READER PORT
TB3
TB4
DOOR MONITOR SWITCH
NORMALLY CLOSED CONTACT *
REQUEST TO EXIT SWITCH
NORMALLY OPEN CONTACT *
(DEFAULT) (DEFAULT)
FIRST READER PORT
TB4
TB3
TB2
FIRST READER PORT
GND
GND
12 Vdc
TR+
TR-
GND
TR+
12 Vdc
GND
TR-
TR+
TR-
FIRST READER PORT
1K,1%
1K,1%
1K,1%
1K,1%
Standard Supervised Circuit,
Normally Closed Contact
Standard Supervised Circuit,
Normally Open Contact
Unsupervised Circuit,
Normally Open Contact
Unsupervised Circuit,
Normally Closed Contact
IN2
IN1
TB1
1
}
+
-
DC STRIKE
DIODE
or MOV
TB5
2-C
NC
NC
NO
1
NO
1-C
TO DC POWER
SOURCE
-
+
AC STRIKE
MOV
FUSE
TB5
1
NO
1-C
NC
NC
NO
2-C
AC
TRANSFORMER
TB1 TB2 TB3
1 1 1
12V
PoE
J3
TB5
1
TB4
1
3
4
S1
2
1
ON
S2
7 6 5 4 3 2 1
J7
J1
J4
J5
BT1
K1
J6
K2
TB1
TB5
RESET SWITCH
.15” [3.81 mm] 2.55” [64.77 mm] 2.55” [64.77 mm] .15” [3.81 mm]
.20” [5.08 mm]
5.40” [137.16 mm]
2.35” [59.69 mm]
.20” [5.08 mm]
2.75” [69.85 mm]
TAMPER
SWITCH
CONNECTION
(J7)
ETHERNET
CONNECTOR
(J6)
PoE/12V DC
POWER SELECTOR
JUMPER (J3)
DIP SWITCHES
STATUS LEDs
CHASSIS GND
Ø .125” [Ø3.175 mm]
6 PL
SOLDER SIDE
RELAY K1 LED
RELAY K2 LED
FIELD WIRING
EP1501 WITH INCLUDED
MOUNTING PLATE
TO ETHERNET
NETWORK
OPTIONAL 3-GANG
JUNCTION BOX
OPTIONAL BLANK
COVER W/SCREWS
OPTIONAL MAGNETIC
TAMPER SWITCH
3.85 [97.8]
2.35 [59.7]
5.50 [139.7]
3.63 [92.1]
3.30 [83.8]
3.63 [92.1]
Ø0.16 [Ø4.0]
MR50 MGT HOLES
4PL
Ø0.16 [Ø4.0]
3-GANG MGT HOLES
4PL
Input Wiring
Inputs are used to monitor door position switches or

unsupervised or supervised. When unsupervised, reporting
consists of only the open or closed states.

not only open and closed but also open circuit, shorted,
grounded*, and foreign voltage*. A supervised input circuit
requires two resistors be added to the circuit to facilitate
proper reporting. The standard supervised circuit requires
1k ohm, 1% resistors, and should be located as close to the
sensor as possible.
*Grounded and foreign voltage states are not a requirement of UL 294

22 AWG minimum required for input wiring. 18 AWG
recommended if wiring request-to-exit devices in series with
locking hardware.

but may not be typical:
TB5
2-C
NC
NC
NO
1
NO
1-C
TO DC POWER
SOURCE
DC MAG LOCK