- 21 -
LTE Filter 800-4G - UHF channels 21..60
LTE Filter 700-5G - UHF channels 21..48
LTE Filter OFF - UHF channels 21..69
OUTPUT VOLTAGE
Select the DC voltage setting function and press
, press
the ▲▼ keys to select the 12V or 24V tension then press
to confirm.
PROTECTION PASSWORD
Select PSW and press
, press the
▲▼
keys to select the
first figure from the right. Press
to confirm. Repeat for
the other figures and press
to confirm.
To remove the protection password, select 000.
AUTO-SCAN THRESHOLD
Adjustable from 45 to 90 dBμV
Select THR, the AUTO-SCAN miminum threshold function
and press
. Use the ▲▼ keys to select the required value
and press
to confirm.
ADVANCED
>LTE: 5G
ADVANCED
>LTE: 4G
LTE: 5G
>DC: 12V
LTE: 5G
>DC: 24V
DC: 24V
>PSW: 000
DC: 24V
>PSW: 000
PSW: 000
>THR: 50dBuV
PSW: 000
>THR: 50dBuV