OAPUMPTEMPHIGH
OAPUMPTEMPHIGH (OA pump laser temperature high)
The LD pack has detected pump laser temperature high.
Severity Major
Service affecting? No
Applicability AHPHG, AHPLG, ALPHG, A2325A, AM2125A, AM2125B,
MESH4, RA2P
Corrective Action
NOTICE
Service-disruption hazard
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure “Reseating a Card” (p. 3-19).
If
there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
This procedure details the corrective action for an OAPUMPTEMPHIGH against the LD
pack.
...................................................................................................................................................................................................
1
Perform the steps in the procedure, “High Temperature Troubleshooting” (p. 3-70).
OCHCOLLISION
OCHCOLLISION (Channel collision)
Trouble-clearing procedures OAPUMPTEMPHIGH (OA pump laser temperature high)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-208
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................