2 — 1830 PSS alarms
2-24 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Name: TCvPcs1Day (3417)
Type: configurationAlarm (11)
Probable cause: T_CV_PCS_1DAY (1246)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the CV-PCS
one-day threshold is crossed.
Name: TCvPcst15Min (3418)
Type: configurationAlarm (11)
Probable cause: T_CV_PCST_15MIN (1247)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the CV-PCS
15-minute threshold is crossed.
Name: TCvPcst1Day (3419)
Type: configurationAlarm (11)
Probable cause: T_CV_PCST_1DAY (1248)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the CV-PCS
one-day threshold is crossed.
Name: TCvs15Min (3420)
Type: configurationAlarm (11)
Probable cause: T_CVS_15MIN (1249)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the CV-S
15-minute threshold is crossed.
Name: TCvs1Day (3421)
Type: configurationAlarm (11)
Probable cause: T_CVS_1DAY (1250)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the CV-S
one-day threshold is crossed.
Name: TCvst15Min (3422)
Type: configurationAlarm (11)
Probable cause: T_CVST_15MIN (1251)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the CV-S
15-minute threshold is crossed.
Name: TCvst1Day (3423)
Type: configurationAlarm (11)
Probable cause: T_CVST_1DAY (1252)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the CV-S
one-day threshold is crossed.
Name: TEs15Min (3424)
Type: configurationAlarm (11)
Probable cause: T_ES_15MIN (1253)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the ES
15-minute threshold is crossed.
Name: TEs1Day (3425)
Type: configurationAlarm (11)
Probable cause: T_ES_1DAY (1254)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the ES
one-day threshold is crossed.
Name: TEsL15Min (3426)
Type: configurationAlarm (11)
Probable cause: T_ES_L_15MIN (1255)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the ES-L
15-minute threshold is crossed.
Name: TEsL1Day (3427)
Type: configurationAlarm (11)
Probable cause: T_ES_L_1DAY (1256)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the ES-L
one-day threshold is crossed.
Alarm Attributes Description
(23 of 37)