2 — 1830 PSS alarms
2-30 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Name: TIAESOtu1Day (3483)
Type: configurationAlarm (11)
Probable cause: T_IAES_OTU_1DAY (1312)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
IAES-OTU one-day threshold is
crossed.
Name:
TnSdhAlarmIndicationSignalRaisedNotif
(2099)
Type: configurationAlarm (11)
Probable cause: AISL (1076)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to AIS
Line/MS
Name: TnSdhLossOfFrameRaisedNotif
(2100)
Type: communicationsAlarm (4)
Probable cause: Lof (1073)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised on Loss of frame.
Name: TnSdhLossOfSignalRaisedNotif (2101)
Type: communicationsAlarm (4)
Probable cause: Los (1077)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised on LOS.
Name: TnSdhSignalDegradeRaisedNotif
(2102)
Type: communicationsAlarm (4)
Probable cause: SigDig (1078)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised on Signal
Degrade.
Name: TnSdhSignalFailureRaisedNotif
(2103)
Type: communicationsAlarm (4)
Probable cause: Sf (1079)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised on Excessive BER.
Name: TnSfpReceiverPwrOORRaisedNotif
(2104)
Type: configurationAlarm (11)
Probable cause: SfpReceiverPwrOOR (1080)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due Pluggable
Module optical receiver power out of
range
Name: TnUserEqptMismatchRaisedNotif
(2105)
Type: configurationAlarm (11)
Probable cause: UserEquipMismatch (1081)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to user
equipment mismatch.
Name: TOprh15Min (3484)
Type: configurationAlarm (11)
Probable cause: T_OPRH_15MIN (1313)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the OPRH
tidemark 15-minute threshold is
crossed.
Name: TOprh1Day (3485)
Type: configurationAlarm (11)
Probable cause: T_OPRH_1DAY (1314)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the OPRH
tidemark one-day threshold is
crossed.
Name: TOprl15Min (3486)
Type: configurationAlarm (11)
Probable cause: T_OPRL_15MIN (1315)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the OPRL
tidemark 15-minute threshold is
crossed.
Alarm Attributes Description