2 — 1830 PSS alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4 September 2011 2-33
3HE 06513 AAAD TQZZA Edition 01 Optical Alarm Reference
Name: TSes15Min (3506)
Type: configurationAlarm (11)
Probable cause: T_SES_15MIN (1335)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the SES
15-minute threshold is crossed.
Name: TSes1Day (3507)
Type: configurationAlarm (11)
Probable cause: T_SES_1DAY (1336)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the SES
one-day threshold is crossed.
Name: TSesL15Min (3508)
Type: configurationAlarm (11)
Probable cause: T_SES_L_15MIN (1337)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the SES-L
15-minute threshold is crossed.
Name: TSesL1Day (3509)
Type: configurationAlarm (11)
Probable cause: T_SES_L_1DAY (1338)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the SES-L
one-day threshold is crossed.
Name: TSesMs15Min (3510)
Type: configurationAlarm (11)
Probable cause: T_SES_MS_15MIN (1339)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the SES-MS
15-minute threshold is crossed.
Name: TSesMs1Day (3511)
Type: configurationAlarm (11)
Probable cause: T_SES_MS_1DAY (1340)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the SES-MS
one-day threshold is crossed.
Name: TSesOdu15Min (3512)
Type: configurationAlarm (11)
Probable cause: T_SES_ODU_15MIN (1341)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
SES-ODU 15-minute threshold is
crossed.
Name: TSesOdu1Day (3513)
Type: configurationAlarm (11)
Probable cause: T_SES_ODU_1DAY (1342)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
SES-ODU one-day threshold is
crossed.
Name: TSesOtu15Min (3514)
Type: configurationAlarm (11)
Probable cause: T_SES_OTU_15MIN (1343)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
SES-OTU 15-minute threshold is
crossed.
Name: TSesOtu1Day (3515)
Type: configurationAlarm (11)
Probable cause: T_SES_OTU_1DAY (1344)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
SES-OTU one-day threshold is
crossed.
Name: TSesP15Min (3516)
Type: configurationAlarm (11)
Probable cause: T_SES_P_15MIN (1345)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the SES-P
15-minute threshold is crossed.
Alarm Attributes Description
(32 of 37)