EasyManua.ls Logo

Alcatel-Lucent 9500 MPR - Purpose and Function

Alcatel-Lucent 9500 MPR
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UDS-101
MSS-8 Microwave Service Switch Shelf
3-8
3EM23952AA
Issue 01, September 2009
MSS-8 shelves supports up to six P2E3DS3 modules in unprotected
configurations. Supports up to three pairs of P2E3DS3 modules in 1+1 EPS
protected configurations. In 1+1 EPS protected configuration, the main
P2E3DS3 modules are equipped in slots 3, 5, and/or 7, and the spare
(protection) P2E3DS3 modules are equipped in slots 4, 6, and/or 8 respectively.
See figure 101-6 to see an example of a stand-alone MSS-8 shelf configured
with two pairs of P2E3DS3s in slots 3 through 6 in the protected 1+1 EPS
configuration and slots 7 and 8 configured in the unprotected configuration.
Figure 101-5. MSS-8 Stand-Alone Shelf, Equipped with P32E1DS1
950-0007-1
072209
CSM
(Protect)
P32E1DS1
(Main)
P32E1DS1
(Protect)
P32E1DS1
(Main)
P32E1DS1
(Protect)
P32E1DS1
(Unprotected)
P32E1DS1
(Unprotected)
CSM
(Main)
Fan
92
4
6
8
1
3
5
7

Table of Contents