Type Message Location Additional Information Action
55 INTERNAL FAULT ON S0
Internal problem detected
on an S0 access following
release message giving
cause as "deactivation of
level 1"
Board location.
Access marker
If the fault
keeps recur-
ring, check
the bus wir-
ing.
58 ISDN BOARD FAULT
A level 1 error was detected
by the board's OBC
Board location.
Access marker
INFO 0 = type of error (not significant) If the fault
keeps recur-
ring, check
the bus wir-
ing.
72 UNSUCCESSFUL AT-
TEMPT TO PRINT
Message sent by the output
device (printer) after every 5
failed print attempts.
Check the
printer and its
connection
cable.
103 OBC FAULT Board location. INFO 0 and 1 = type of fault
200 4070 IO/EO BASE: SLAVE
LINK CONNECTED TO IN-
VALID INTERFACE
Board location.
Interface mark-
er
INFO 0 = interface number invalid
INFO 1 = base station operating status
Check the
cables on the
2nd link in the
base station
201 4070 IO/EO BASE: FRE-
QUENCY REJECTION
Discrepancy between the
number of frequencies con-
figured by the installer and
the number of DECT fre-
quencies processed
Board location.
Interface mark-
er
INFO 0 to 3 = bitmap of frequencies
authorized and in use
For more information, refer to the "In-
stalling 4070 IO/EO base stations", file
in the "Mobility" section.
202 4070 IO/EO BASE: LOSS
OF SYNCHRONIZATION
ON UA LINK 0
Board location.
Interface mark-
er
INFO 0 = link status (0 = link KO; 1 =
link OK)
Check cabling
Replace the
4070 base
station
203 4070 IO/EO BASE: LOSS
OF SYNCHRONIZATION
ON UA LINK 1
Board location.
Interface mark-
er
INFO 0 = link status (0 = link KO; 1 =
link OK)
Check cabling
Replace the
4070 base
station
204 4070 IO/EO BASE: NO
REPLY ON DSP PRESENT
(RESET)
Board location.
Interface mark-
er
205 4070 IO/EO BASE: TRANS-
MISSION ERRORS DE-
TECTED ON SERIAL LINK
TO DSP (RESET)
Board location.
Interface mark-
er
Chapter
6
% *
26/62
 ! "#$ ! % $& !     

Other manuals for Alcatel-Lucent OmniPCX Office

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniPCX Office and is the answer not in the manual?

Alcatel-Lucent OmniPCX Office Specifications

General IconGeneral
VoIP ProtocolsSIP, H.323
Power Supply100-240 VAC, 50/60 Hz
Humidity10% to 90% non-condensing
TypeIP PBX
Maximum TrunksUp to 60
Voice codecsG.711, G.729
Network Interfaces10/100 Ethernet
WeightVaries depending on the model/configuration