• MS: Missing Signal
• RFA: Remote Frame Alarm
- the call detail record storage buffer is 70% full (default value) (message 70)
- counting printer fault (message 72); this alarm is only transmitted if the "PrintFault" flag is
other than 0
- problem regaining ISDN access (message 50)
- electrical power supply fault (message 123)
- the hardware message table is 80% full (message 160); this alarm is only transmitted if the
"OperAlarm" flag is other than 0
- erroneous NMC call (message 171)
- unanswered NMC call (message 172)
- NMC communication failure (messages 173, 174 or 175)
- NMC: alarm report failure (message 176)
- NMC: PCX not registered (message 177)
- NAND Flash memory (CPU ) or hard disk not detected (message 239)
6.7 Urgent alarms
OmniPCX Office Rich Communication Edition will generate a call to the network management
center (NMC) if any of the following alarms is detected:
- the system reboots (message 0)
- the system is operational after start-up (message 11)
- either of the 2 following T2 alarms (message 53):
• MS: Missing Signal
• RFA: Remote Frame Alarm
- the ISDN protocol management module detected a level 1-fault on an ISDN access
(message 56)
- the call detail record storage buffer is 70% full (default value) (message 70)
- counting printer fault (message 72); this alarm is only transmitted if the "PrintFault" flag is
other than 0
- the board is back in service after a system stoppage or after being unplugged (message
100)
- the board is disconnected (message 101)
- the board is permanently reset (message 105)
- the board is refused (message 106)
- the board info has been erased by MMC (message 109)
- the module is back in service (message 120)
- the module is disconnected (message 122)
- there is a power supply problem (message 123)
% *
! "#$ ! % $& !