TESTED and LISTED to
CAN/ULC S627 AND UL 1482
Meets the Environmental Protection Agency’s
July 1990 Particulate Emission Standards
PLEASE SAVE THESE INSTRUCTIONS
By Paci c Energy
INSTALLATION & OPERATION GUIDE
ALDERLEA T6 CAST IRON WOOD STOVE
MODEL: ALDERLEA T6
(STANDARD OR CLEARVIEW DOOR)
SERIES: B
SAFETY NOTICE
If this stove is not properly installed, a house  re may result. For your safety,
follow the installation instructions. Contact local building or  re officials about
restrictions and installation inspection requirements in your area.
190313-24 AL6B
5055.3272
SERIAL #

Questions and Answers

  • J
    Jasmine HughesJul 27, 2025
    Why is the glass on my Alderlea T6 getting dirty?
    • A
      Amanda GregoryJul 27, 2025
      The glass on your Alderlea Wood stove might be getting dirty due to several reasons: * The wood you're using is wet. To fix this, use dry wood. * You're turning down the air control or damper too soon. Don't adjust it until you have a good bed of coals and the wood is charred. * There's a draft issue, possibly due to improper chimney height or diameter. Consult your dealer. * The door gasket is leaking. Replace the gasket and check the latch for proper operation.
  • L
    Laurie RiosAug 2, 2025
    Why is the heat output so low on my Alderlea T6 Wood stove?
    • G
      Gabrielle BakerAug 3, 2025
      If your Alderlea Wood stove isn't producing enough heat, it could be due to: * Using wet wood. Make sure to use dry wood. * The fire is too small. Build a larger fire. * There is a draft issue because the chimney is plugged or restricted. Inspect and clean the chimney.
  • E
    Elizabeth MckayAug 10, 2025
    What to do if my Alderlea T6 won't burn overnight?
    • J
      Julia BrownAug 10, 2025
      If your Alderlea Wood stove won't burn overnight, consider these potential causes: * The air control is set too high. Try setting it lower. * Not enough wood is being used. Unsplit wood is better for overnight burns. * The draft is too high due to excessive chimney height or diameter. * The wood quality is poor, or the wood is wet. Use good quality, dry wood.
  • S
    swansonjustinAug 18, 2025
    How to fix wood that won't burn in my Alderlea T6 Wood stove?
    • A
      Angela HancockAug 18, 2025
      If the wood in your Alderlea Wood stove isn't burning, it could be because: * The combustion air supply is blocked. Check the outside air supply for any obstructions. * The draft is too low. This could be because the chimney is plugged or restricted (inspect and clean it) or the chimney is oversized or unsuitable (consult your dealer).

Summary

Safety and Maintenance

Maintenance Checks

Blower Maintenance

Instructions for cleaning the stove's blower to ensure optimal operation and prevent dust buildup.

Creosote

Formation and Need for Removal

Explains how creosote forms, the risks involved, and the importance of its removal from the chimney.

Chimney Fires

Avoiding a Chimney Fire

Provides essential steps and practices to prevent chimney fires from occurring.

If You Suspect a Chimney Fire

In Case of a Chimney Fire

Immediate actions to take and post-fire procedures for safely handling a chimney fire.

Appliance Dimensions

Outside Air Opening Dimensions

Details and diagrams showing the dimensions for the stove's outside air intake.

Installation - Residential

Clearances - Residential

Specifies required safe clearances to combustible materials for residential installation.

Chimney and Connector - Residential

Double-Wall Connector - Residential

Guidelines for using a double-wall connector in residential chimney installations.

Single-Wall Connector - Residential

Guidelines for using a single-wall connector in residential chimney installations.

Installation Procedure - Residential

Installation - Mobile Home

Clearances - Mobile Home

Specifies required safe clearances to combustible materials for mobile home installations.

Installation Procedure - Mobile Home

Listed Chimney and Chimney Connector for Mobile Home Installation

Lists compatible chimney and connector systems for mobile home installations.

Floor Protector

Combustion Air

Operation

Wood Selection

Guidance on selecting the appropriate type of wood for burning in the stove for efficiency and low emissions.

How to Test Your Wood

Methods to determine if wood is properly seasoned and ready for burning.

Lighting for the First Time

Curing of the Paint Finish

Instructions for baking the stove's paint finish during the initial burns for optimal durability.

Lighting a Fire

Restarting After Extended or Overnight Burns

More Wood, More Heat

Proper Draft

Ash Removal

Disposal of Ashes

Baffle Removal

Secondary Air Box Removal and Cleaning

Instructions for removing and cleaning the secondary air box assembly.

Optional Blower

Blower Operation

Guidance on operating the optional blower for optimal performance and heat distribution.

Troubleshooting

Glass is Dirty

Addresses issues with dirty glass, its causes, and recommended solutions.

Excessive Creosote Buildup

Troubleshooting steps for excessive creosote buildup in the chimney.

Low Heat Output

Diagnosing and resolving issues related to low heat output from the stove.

Wont Burn Overnight

Solutions for preventing the fire from going out overnight.

Wood Wont Burn

Troubleshooting steps when the wood fails to ignite or burn properly.