Assembly/Adjustment setup
charging is complete to maximize charge cycles of the battery and not waste power.
Batteries can become faulty over time, individual cells in the battery can fail and the battery could
short. The charger will not charge faulty batteries. Use another battery, if possible, to check correct
functionality of the charger and purchase a replacement battery if a faulty battery is indicated.
DO NOT store lithium-ion battery packs in a discharged state over a long period as this can damage
the lithium-ion cells. For long-term storage, store batteries in a high charge state disconnected from
the power tool.
The capacity of batteries will reduce over time. After 100 charge cycles, the battery’s operation time
and the maximum torque performance of the driver will slightly reduce. This decline will continue until
the battery has minimal capacity after 250 charge cycles. This is normal and not a fault with the
battery.
Installing/Removal the Saw Blade
WARNING: Before any work on the power tool, remove the battery.
●
●
●
For changing the cutting tool, it is best to place the machine on the face side of the motor housing.
●
●
●
●
●
Dust/Chip Extraction
Dusts from materials such as lead-containing coatings, some wood types, minerals and metal can be
harmful to one’s health. Touching or breathing-in the dusts can cause allergic reactions and/or lead to
respiratory infections of the user or bystanders, certain dusts, such as oak or beech dust, are consid-
ered as carcinogenic, especially in connection with wood-treatment additives (chromate, wood
preservative). Materials containing asbestos may only be worked by specialists.
-
-
-
When mounting the saw blade, wear protective gloves. Danger of injury when touching the saw
blade.
Only use saw blade that correspond with the characteristic data given in the operating instructions.
Do not under any circumstances use grinding discs as the cutting tool.
Press the spindle lock and keep it pressed.
The spindle lock button may be actuated only when the saw spindle is at a standstill. Otherwise, the
power tool can be damaged.
With the Allen key, unscrew the clamping bolt in clockwise direction.
Tilt back the retracting blade guard and hold firmly.
Remove the clamping flange and the saw blade from the saw spindle.
To achieve a high level of dust extraction, use a suitable dust extractor together with this power tool.
Provide for good ventilation of the working place.
It is recommended to wear a P2 filter-class respirator.
- 12 -