Impeller device/ all types of agitator Supplier Instruction Weekly Monthly Half-yearly
Sticky media
- Clean impeller device X
Abrasive media
- Check blade thickness* X
- Check fastening of pointed set screws X
*If any suspicion of reduction in blade thickness, contact Alfa Laval and inform serial no. stated on the name plate
Guidance/ support for ALT/ ALTB Supplier Instruction Weekly Monthly Half-yearly
- Shaft rotation — radial movement < 5mm
- Bushing: BS1, BS3 X
- Bushing: BS1 with Abrasive media X
- Bushing: BS2, MS2 X
Scheduled maintenance intervals
To ensure that your agitator operates ef
ficiently, it is essential to follow a simple preventive maintenance programme, which will
keep your machine in good working conditions. Good maintenance requires careful attention at regular intervals. The following
recommended preventive maintenance procedures are based on the average operating conditions of most Alfa Laval agitators.
However, you will appreciate that a machine, which is subject to rough and dirty conditions, will need more frequent attention
than one working in ideal conditions. We trust that you will adjust your maintenance programme to meet the demands of your
normal operating conditions.
Replace every:
Shaft sealing for ALS/ALB
3000 hours or yearly
3000 hours or every
3rd year
6000 hours or every
3rd year
10000 hours or every
3rd year
- Not flushed mechanical seal: S1, S2, S3 X
- Mechanical seal/shut down seal: S3SD X
- Flushed mechanical seal: DC, D X
Shaft sealing for ALT/ALTB 3000 hours or yearly 3000 hours or every
3r
d year
6000 hours or every
3rd year
10000 hours or every
3rd year
- Radial seal: R X
- Gab seal: G X
- V
-ring seal: V X
- Not flushed mechanical seal: S, S3 X
- Flushed mechanical seal: DC, D X
Bearing frame for ALS/ALB/ALT/ALTB 3000 hours or yearly 3000 hours or every
3r
d year
6000 hours or every
3rd year
10000 hours or every
3rd year
- Spider type coupling (if any X
- Static seals X
- Radial seals X
- Bearings,rmp700 X
- Bearings,rmp700 X
Guidance/support for ALT/ALTB 3000 hours or yearly 3000 hours or every
3rd year
6000 hours or every
3rd year
10000 hours or every
3rd year
- Bushing: BS1, BS3 X
- Bushing: BS2, MS2 X
- Bushing: BS1, BS2, MS2 Replace if temperature > 100°C
Agitator service tool example
Shaft retainer tool - a very useful tool during maintenance of top mounted agitators (ALT / AL
TB). Designed to support agitators
at a weight up to 500 kilogram. For more information please refer to the manual.
Description Item no.
Shaft diameter between Ø30 and Ø60 TE2608084880
The guidelines may not apply in all working conditions. Please contact Alfa Laval for information relating to specific applications