6
“PRINT” is displayed with the serial number of your ALFANO. Press the right button: the system starts the infrared output of all
saved data and shows the individual serial number in the display. Note : Each ALFANO has a unique serial number.
4
th
Impulse to the left button: this takes you to the Main Menu 1, sub-menu - 4 - :
RESET “reset”
“RESET” s’affiche avec le numéro de série de votre ALFANO. Reset is displayed with the serial number then an impulse on the
right button the system returns to the STOP Mode once the memory has been cleared. Meantime a little animation appears on
the screen.
NOTE : The RESET does not affect the parameters and the engine running time counters.
5
th
Impulse to the left button: this takes you to the Main Menu 1, sub-menu - 5
ACCESS TO MAIN MENU 2 :
THE ENGINE “RPM” GRAPHICS AND SYSTEM CONFIGURATION “Conf SYSt - recall motor”
- Push the right button and you enter in the Main Menu 2.
- Push the left button, and you return to STOP Mode .
MAIN MENU - 2
Once you have accepted the access to Main Menu 2 you are now in the
Sub-Menu - 6 - :
ENGINE “RPM” GRAPHICS “recall motor”
This option is a numerical graphic. It gives you the running time for each 640 RPM bracket, this being calculated for the best lap
time. The 1
st
bracket is between 5,120rpm and 5,760 rpm. The last bracket between 24,320 rpm and 24, 960 rpm. (For a total
of 31 brackets).
2
nd
Impulse to the left button: this takes you to the Main Menu 2,
sub-menu -7- :
ENGINE RPM TYPE SETTINGS : M or D “Conf dSPL”
Select « M » or « D »with the right button
M = MAXIMUM, displays the highest rpm for the previous lap.
The display remains during the next lap.
D = DIRECT, direct rpm display.
3
rd
Impulse to the left button: this takes you to the Main Menu 2,
sub-menu - 8 - :
ENGINE STROKE TYPE SETTINGS (IGNITION:1, 2, 4, 8 STROKE) “Conf Stro”
With the right button, you select your ignition type:
1 Stroke = number 2 and 4 are off
2 Stroke = Only number 2 is on
4 Stroke = Only number 4 is on
8 Stroke = number 2 and 4 are on
WARNING ! A bad configuration unavoidably leads to a defective reproduction of data.
4
th
Impulse to the left button: this takes you to the Main Menu 2,
sub-menu - 9 - :
NUMBER OF MAGNETIC STRIPS SETTINGS : 1, 2, or 3 “Conf Sect”
Select with the right button the number of magnetic strips integrated in the track. If this parameter has been changed, the system
automatically executes a RESET and return in fashion STOP.
WARNING ! A bad configuration unavoidably leads to a defective reproduction of data.
5
th
Impulse to the left button: this takes you to the Main Menu 2,
sub-menu -10 - :
TEMPERATURE SENSOR TYPE and MEASUREMENT UNIT SETTINGS :
“Conf T1 C, T2 C, T1 F or T2 F”
With the right button you select your sensor type and your measurement unit: