EasyManuals Logo

Algodue ELETTRONICA UPM307 Protocol Manual

Algodue ELETTRONICA UPM307
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
7-4
ENGLISH
Registers table
MODBUS protocol manual
$0030 2 SYSTEM APPARENT POWER [0.1kVA] (Signed 32bit)
$0032 2 PHASE 1 POWER FACTOR [-] (Signed 32bit)
$0034 2 PHASE 2 POWER FACTOR [-] (Signed 32bit)
$0036 2 PHASE 3 POWER FACTOR [-] (Signed 32bit)
$0038 2 SYSTEM POWER FACTOR [-] (Signed 32bit)
$003A 2 VOID [-] (-)
$003C 2 VOID [-] (-)
$003E 2 VOID [-] (-)
$0040 2 VOID [-] (-)
$0042 2 VOID [-] (-)
$0044 2 VOID [-] (-)
$0046 2 VOID [-] (-)
$0048 2 VOID [-] (-)
$004A 2 VOID [-] (-)
$004C 2 SYSTEM ACTIVE POWER DMD [0.1kW] (Signed 32bit)
$004E 2 SYSTEM APPARENT POWER DMD [0.1kVA] (Signed 32bit)
$0050 2 VOID [-] (-)
$0052 2 PEAK OF SYSTEM ACTIVE POWER DMD [0.1kW] (Signed 32bit)
$0054 2 PEAK OF SYSTEM APPARENT POWER DMD [0.1kVA] (Signed 32bit)
$0056 2 VOID [-] (-)
$0058 2 PHASE ORDER (0 or 1) [-] (Signed 32bit)
$005A 2 IMPORTED ACTIVE ENERGY [kWh] (Unsigned 32bit M10K)
$005C 2 EXPORTED ACTIVE ENERGY [kWh] (Unsigned 32bit M10K)
$005E 2 TOTAL ACTIVE ENERGY [kWh] (Unsigned 32bit M10K)
$0060 2 NET ACTIVE ENERGY [kWh] (Unsigned 32bit M10K)
$0062 2 IMPORTED REACTIVE INDUCTIVE ENERGY [kvarh] (Unsigned 32bit M10K)
$0064 2 EXPORTED REACTIVE INDUCTIVE ENERGY [kvarh] (Unsigned 32bit M10K)
$0066 2 TOTAL REACTIVE ENERGY [kvarh] (Unsigned 32bit M10K)
$0068 2 NET REACTIVE ENERGY [kvarh] (Unsigned 32bit M10K)
$006A 2 TOTAL APPARENT ENERGY [kVAh] (Unsigned 32bit M10K)
$006C 2 PHASE 1 VOLTAGE THD [m%] (Unsigned 32bit M10K)
$006E 2 PHASE 2 VOLTAGE THD [m%] (Unsigned 32bit M10K)
$0070 2 PHASE 3 VOLTAGE THD [m%] (Unsigned 32bit M10K)
$0072 2 PHASE 1 CURRENT THD [m%] (Unsigned 32bit M10K)
$0074 2 PHASE 2 CURRENT THD [m%] (Unsigned 32bit M10K)
$0076 2 PHASE 3 CURRENT THD [m%] (Unsigned 32bit M10K)
$0078 2 VOID [-] (-)
NOTE: Unsigned 32 bit M10K format
The Modulo-10000 (M10K) format breaks a 32-bit value into two 16-bit registers, according to the
following relationship:
The following registers are available only in Read Only (RO) mode. This mode is not programmable
via serial port but it must be set manually on the instrument.
Reg. Word Description U. M. Format

Other manuals for Algodue ELETTRONICA UPM307

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Algodue ELETTRONICA UPM307 and is the answer not in the manual?

Algodue ELETTRONICA UPM307 Specifications

General IconGeneral
BrandAlgodue ELETTRONICA
ModelUPM307
CategoryMeasuring Instruments
LanguageEnglish