7-8
ENGLISH
Registers table
MODBUS protocol manual
7.5 Read & Write parameters (Function code $03 & $10)
$E020 1 LOGICAL NUMBER (1÷247) $0001÷$00F7 YES
$E028 1 BAUDRATE 0=300 baud YES
-read only for MODBUS TCP- 1=600 baud
2=1200 baud
3=2400 baud
4=4800 baud
5=9600 baud
6=19200 baud
7=38400 baud
8=57600 baud
$E029 1 PARITY 0=none (fixed) YES
$E02A 1 DATA BITS 0=7 bit (ASCII) YES
-read only for MODBUS TCP- 1=8 bit (RTU)
$E031 1 CT RATIO (1÷9999) $0001÷$270F YES
$E032 1 FSA VALUE (1-5A) 0=1 A YES
1=5 A
=5A
$E034 1 PT RATIO (1÷9999) $0001÷$270F YES
$E038 1 WIRING MODE 1=1-phase YES
3=3-phases 3wires/3CTs
4=3-phases 4wires/3CTs
5=3-phases 3wires/1CT
6=3-phases 2wires/1CT
7.4 Read only parameters (Function code $03)
$E000 5 SERIAL NUMBER 10 ASCII characters,
do not consider the first one
$E005 7 VERSION NUMBER 14 ASCII characters,
do not consider the first tenth
$E00C 1 INSTRUMENT MODEL CODE $0013 (fixed for this model)
$E00F 1 NUMBER OF DIGITAL OUTPUTS 2=2
$E011 1 NUMBER OF DIGITAL INPUTS * 0=none, 1=1
Register Word Description Range/Values
Register Word Description Range/Values Reset