18
PV Cutoff%
0.00
DampingS
1.0
Low Cut
Set by and keys. Available input is 0%~20%.
Press to enter next setting interface.
Damping
Set by and keys. Available time is 0~64s.
Press to enter next setting interface.
Gauge pre.(Kpa)
1000.00
Density(kg/m3)
1.025
Gas Pressure (gauge pressure)
Set by and keys. This is used for inputting pressure (unit: Kpa) manually (in Pressure
Measure window). This value is pressure value for temperature/pressure compensation when it is
on. If measuring liquid, no such option is
available. Press to enter next setting interface.
Fluid Density
Set by and keys. Gas density (unit: kg/m3); liquid density (unit: g/cm3)
Press to enter next setting interface.
Total Reset
NO
Totalizer Reset
Set by and keys. Choose YES and then press long to reset totalizer.
Press to enter next setting interface.
Total Overflow
0.000
Totalizer Overrange Cycle
This interface is read only. When flow total is over 99999999, the overrange cycle will be 1. And
then flow total will start accumulating from 0 again.
Press
to enter next setting interface.
Gas Temperature (Celsius)
Set by and keys. This is used for inputting temperature (unit ) manually (in Temp.Measure
window). This value is temperature value for temperature/pressure compensation when it is on. If
measuring liquid, no such option is
available. Press to enter next setting interface.
Temperature()
20.000
Disp. Point
1
Decimal point
Press or to set decimal point, 3 decimal points at most.
Press
to enter next setting interface.
Display Mode
3_Line Display
Display Mode
Press or to set display mode.
2_Line Display: LCD only shows flow rate and totalizer.
3_Line Display: LCD shows Flow rate and totalizer+frequency/density/pressure/temperature/current/
percentage /P&T.
Press
to enter next setting interface.