Equipment Phase Instructions 
 
434  Rockwell Automation Publication 1756-RM006K-EN-P - November 2018 
Function Block 
This instruction is not available in function block. 
Structured Text 
PXRQ (Phase_Instruction, External_Request, Data_Value); 
Operands 
Ladder Diagram 
Operand  Type  Format  Description 
Phase Instruction  PHASE_INSTRUCTION  tag  Tag that controls the operation. 
External Request  request  enumeration value  Type of request. 
Data Value  DINT  array tag  Parameters of the request. 
Structured Text 
The operands are the same as those for the Ladder Diagram PXRQ instruction. 
PHASE_INSTRUCTION Data Type 
If want to: 
Then check or 
set this 
member: 
Data type  Notes 
Determine if a false-to-true transition caused 
the instruction to execute 
EN  BOOL  Refer to the timing diagram below. 
Determine if the request failed  ER  BOOL  Refer to the timing diagram below. 
To diagnose the error, refer to the ERR and 
EXERR values. 
Determine if the FactoryTalk Batch software 
completed its processing of the request 
PC  BOOL  Refer to the timing diagram below. 
Determine if the FactoryTalk Batch software is 
processing the request 
IP  BOOL  Refer to the timing diagram below. 
Determine if the instruction sent the request 
but FactoryTalk Batch software has not yet 
acknowledged it 
WA  BOOL  Refer to the timing diagram below. 
WA also = 0 if: 
•  The connection times out 
•  A network error occurs 
•  ABORT = 1 
Cancel the request  ABORT  BOOL  To abort (cancel) the request, set the ABORT 
bit = 1. When the controller aborts the 
instruction: 
•  ER = 1 
•  ERR shows the result of the abort