2-2 Product Features
Engineering Data
(Reference Values)
Specifications
0 12345
1,000
500
100
50
10
Switching operations ( 10
4
)
250V DC/30V
cos =1
250V A C cos =0.4
Load current (A)
30V DC L/R=7 ms
Reference:A maximum current of 0.15 A can be switched
at 125V DC (cosφ=1) and a maximum current of 0.1 A
can be switched if L/R is 7 ms. In both cases, a life of
100,000 operations can be expected. The minimum
applicable load is 10 mA at 5V DC (failure level: P).
Electrical Ratings
Pilot Duty Rating NEMA B300
Rated supply voltage 100 to 240V AC, 24V AC/12 to 24V DC (50/60Hz) (permissible
ripple: 20%(p-p) max.)
Operating voltage range 85%110% of rated supply voltage
Power consumption 100240V AC
24V AC/12…24V DC
4.3 VA
3.4 VA/1.7 W
Inrush Current 100…240V AC
24V AC/12…24V DC
3 A
5 A
Make 240V AC
30 A
15 A
Break 240V AC
3 A
1.5 A
Hp at 120V AC 1/4 Hp
Hp at 240V AC 1/3 Hp
Mechanical
Mounting method Flush mounting, surface mounting, DIN mounting
Display 7-segment, negative transmissive LCD;
Present value (red, 8 mm high characters); Set value (green,
4 mm high characters)
Digits 4 digits
Timer Time ranges 0.000…9.999 s, 0.00…99.99 s, 0.0…999.9 s, 0…9999 s,
0 min. 0.0 s…99 min. 59 s, 0.0…999.9 min., 0 h 00 min.…99
h 59 min., 0.0 h999.9 h, 0 h9999 h
Timer modes Elapsed time (Up), remaining time (Down), selectable
Output modes A, A-1, A-2, A-3, B, B-1, D, E, F, Z, ton or toff
120V AC