Allflex NX Series Operational Manual
Page 9 of 14
5.0 POWER
Power requirement. Use the 12vdc power cable supplied and connect to a 12vdc power source.
An external 12-volt battery can be used, or a regulated linear power supply. DO NOT USE A SWITCH
MODE POWER SUPPLY as some switch mode power supplies can interfere with the performance of the
system. Voltage range is 12vdc to 14vdc.
The power supply must be approved for use in your country and meet all your countries emission requirements
Only use high quality regulated linear power supplies or solar panels. Please contact Allflex with any queries,
you may have. Some switch mode power supplies are NOT suitable and must not be used.
6.0 CONNECTION INTERFACE
The NX-M supports multiple connection methods to external devices. These include; Bluetooth, WiFi, Serial
and USB. Each connection uses a common connection interface.
See the table below for a full list of commands included in the interface. Each command should be entered
followed by a character return.
list all command information
get information about a command
Same as s but with START/END
Same as sa but with START/END
get current value of a setting
change the value of a setting
exit and restart NX-M software