EasyManua.ls Logo

Alliance Laundry Systems BWT820*N1102 - 21. Coin Slide Fully Inserts, Switch Does Not Activate

Alliance Laundry Systems BWT820*N1102
130 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39201 41
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting (Coin Slide Operated/Non-Metered Models with “8” or “9” in 4th Character of Model No.)
21. Coin Slide Fully Inserts, Switch Does Not Activate
Switch isn't activated when coin
slide is fully inserted.
Was the wrong
extension lever
setup used?
Are coin slide
extension lever
and flat washers
(shims) installed
correctly?
Refer to
Installation
manual. Extension
lever should rotate
freely after assembly.
Extension lever
shouldn't have
excess play.
No
TLW1837B
Is the switch
activation lever
bent or out of
position?
Correct lever or
replace switch
mount assembly.
Yes
No
Make sure one or two
stars, depending on
type of coin slide,
face down. Refer to
Installation
manual.
Yes
Switch activation
lever doesn't rotate
under the force of
the coin slide
extension lever?
Friction wave
washer in switch
mount assembly
is too tight.
Compress wave
washer slightly
and retest, or
replace switch
mount assembly.
Yes
Is wiring
connected
correctly?
Examine wiring
and terminals
for proper
connections.
Refer to wiring
diagram.
No
No
Yes
No

Table of Contents