© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
F232204R5
68
6. Rotate spring clockwise, 40 to 60 degrees, until it
is free from right tabs. Refer to Figure 15.
7. Use screwdriver to remove spring from center
tab. Refer to Figure 14.
8. Lift spring, with attached clip, off drop.
9. Remove clip from spring. Refer to Figure 16.
10. Attach clip to new tension spring, Part No.
209/00598/02.
11. Place clip, installed on spring, in slot on coin
drop. Refer to Figure 17.
12. Use a small flathead screwdriver to push spring
under center tab. Refer to Figure 18.
13. Lift spring gently to place in position under left
tab.
14. Push spring to right until it snaps into position.
Refer to Figure 14.
15. Close coin drop cover.
16. Move tension spring over cover catch. Refer to
Figure 13.
Reinstall Coin Drop Into Machine
1. Reinstall coin drop into machine.
2. Reconnect electrical power to machine and drop.
3. Add a coin to drop to verify that coin drop is
operating properly and that electrical connection
is working properly.
Figure 15
Figure 16
Figure 17
Figure 18
MIX5B
Small Flat
Screwdriver
Center
Tab
Left Tab
www.groupdynamics-laundry.com
sales@groupdynamics.lv