Installation
45
F232135
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electrical Specifications
18 and 20 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
2 Speed Models
B 110 – 120 60 1 2 15 20 12 4 N/A
C 380 – 415 50 3 4 4 15 14 2.5 14 15 14 2.5
D 220 – 240 50 3 3 5 15 14 2.5 24 25 10 6
E220 2405012102012 4 4245 6 16
F 440 – 480 60 3 3 4 15 14 2.5 16 20 12 4
H 380 60 3 3 4 15 14 2.5 13 15 14 2.5
J 200 50 3 3 5 15 14 2.5 24 25 10 6
O 208 – 240 60 3 3 5 15 14 2.5 24 25 10 6
Y208 2406012102012 4 4245 6 16
Variable-Speed Models
Q 200 – 240 50/60 3 3.8 3.8 15 14 2.5 N/A N/A N/A N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Table 9
Electrical Specifications
25, 27 and 30 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
2 Speed Models
C 380 – 415 50 3 4 4 15 14 2.5 15 20 12 4
D 220 – 240 50 3 3 6 15 14 2.5 24 25 10 6
E220 2405012102012 4 4245 6 16
F 440 – 480 60 3 3 4 15 14 2.5 16 20 12 4
H 380 60 3 3 4 15 14 2.5 14 15 14 2.5
J 200 50 3 3 6 15 14 2.5 20 25 10 6
O 208 – 240 60 3 3 7 15 14 2.5 25 30 10 6
Y 208 – 240 60 1 2 10 20 12 4 43
45616
Variable-Speed Models
Q 200 – 240 50/60 3 3 4.8 15 14 2.5 N/A N/A N/A N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Tabl e 10