EasyManua.ls Logo

Alliance Laundry Systems YTEE5ASP283CW01 - Gas Dryer Burner Ignites and Goes Out Repeatedly

Alliance Laundry Systems YTEE5ASP283CW01
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
806221 33
Dryer Control Troubleshooting
15. Burner Ignites and Goes Out Repeatedly – Gas Dryer Models
Gas dryer models: Burner ignites
and goes out repeatedly.
Is exhaust
system
improper or
inadequate?
Refer to
Installation
Instructions
(supplied with
unit) for
exhaust
requirements.
Yes
Is weather
hood flapper
restricted?
No
Is burner heat
holding sensor
contacts open?
Replace sensor
or correct gas
supply problem.
No
No
SWD1696S
Refer to
Installation
Instructions
(supplied with
unit) for
exhaust
requirements.
Yes
Is gas supply
insufficient?
Check gas supply
and pressure.
Make sure gas
shut-off valve is
turned on.
Is igniter
cracked?
Replace igniter
and bracket.
Are gas valve
coils
inoperative or
intermittent?
Check coils and
replace
appropriate coils.
Refer to Dryer
Test Procedures
section.
No
Yes
No
Yes
Yes
Yes

Table of Contents

Related product manuals