Installation/Operation/Maintenance
www.alliancelaundry.com
Tumble Dryers
50 Pound (22.7 Kilogram) Capacity
75 Pound (34 Kilogram) Capacity
Starting Serial No. 0904004427
Refer to Page 6 for Model Identification
TMB1277
Part No. 70457901ENR7
September 2013
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
TMB1277C

Table of Contents

Questions and Answers

  • A
    Anne NavarroAug 6, 2025
    What to do if spark on, but no flame in ALLIANCE Dryer?
    • K
      Kristin SmithAug 6, 2025
      If you observe a spark but no flame in your ALLIANCE Dryer, try the following: * First, verify that the gas supply is turned on. * Next, check for 24 VAC at the gas valve. * If these steps don't resolve the issue, there may be a bad control. In this case, check the voltage between the gas valve terminal MV and GND on the control.
  • J
    Jessica WrightAug 12, 2025
    What to do if valve on, but no spark during TFI in ALLIANCE HT075N?
    • A
      Adam FosterAug 12, 2025
      If the valve is on but there is no spark during TFI (Trial For Ignition) in your ALLIANCE Dryer, consider these possible solutions: 1. Check for a shorted electrode. 2. Ensure the spark gap is correctly set between .094 and .156 inch. 3. Inspect the high voltage cable for faults or poor connections. 4. It is also possible that there is a control failure.
  • C
    Crystal WilliamsAug 16, 2025
    Why is ALLIANCE HT075N control in lockout mode?
    • C
      christian85Aug 16, 2025
      If the control in your ALLIANCE Dryer is in lockout mode (70458701 Control Only), a manual reset of the control is needed. You can reset it by pushing the red lockout button or by using the front end control.
  • A
    Ashley HawkinsAug 21, 2025
    What to do if thermostat on, but there is no spark or valve in ALLIANCE HT075N?
    • P
      Phillip ClarkAug 21, 2025
      If the thermostat is on but there is no spark or valve activity in your ALLIANCE Dryer, verify that the cable connects to the control and electrode and that voltage is present at the gas valve. Also, check the red LED for steady on or flashing codes, as it may indicate a bad control.
  • L
    Lindsey RodriguezAug 26, 2025
    How to fix reset failure in ALLIANCE HT075N Dryer?
    • R
      Raymond WoodsAug 27, 2025
      If you're experiencing a reset failure with your ALLIANCE Dryer, it might be because the reset switch was pressed for too long. Try resetting it again. If the issue persists, the reset switch might be shorted and need replacement.
  • S
    Samantha MccarthyAug 31, 2025
    What to do if ALLIANCE Dryer control does not start and green LED is off?
    • S
      Steven MendozaSep 1, 2025
      If the control of your ALLIANCE Dryer does not start and the green LED is off, ensure that there is 24 VAC present between 24V and ground (on 70458701 control only). If not, refer to the machine schematic. Also, check for 24 VAC between TH and ground; if absent, consult the machine schematic.

Summary

Introduction

Model Identification

Lists all model numbers and their configurations.

Contact Information

Provides contact details for service and parts.

Safety Information

Important Safety Instructions

Crucial precautions for safe operation and maintenance.

Specifications and Dimensions

Cabinet Dimensions

Detailed measurements for physical installation and clearances.

Exhaust Outlet Locations

Specifies locations and dimensions for exhaust ports.

Gas Connection Locations

Details the placement and size of gas inlets.

Electrical Connection Locations

Shows where electrical connections are made.

Steam Connection Locations

Indicates the position of steam inlets and fittings.

Installation

Pre-Installation Inspection

Steps to check the unit and prepare for installation.

Location Requirements

Guidelines for choosing a suitable and safe installation site.

Position and Level the Tumble Dryer

Instructions on placing and leveling the unit for operation.

Fire Suppression System

Information and requirements for the fire suppression system.

Water Requirements

Details on water supply needs for the fire suppression system.

Water Connections

Steps for connecting water supply lines to the machine.

Electrical Requirements

Information on electrical hookup and safety.

Bolt-On Angle Option

How to reduce dryer depth for tight spaces.

To Reverse the Loading Door

Instructions for changing the door hinge.

Before Placing Tumble Dryer into Service

Final checks and procedures before operating the dryer.

Basic Configuration

Steps for setting up the dryer for specific gas types and regions.

CE Orifices

Details on gas orifices for CE models and gas properties.

Exhaust Requirements

Layout

Guidelines for dryer placement concerning exhaust.

Make-Up Air

Requirements for providing adequate air supply.

Venting

Recommendations for proper exhaust ducting and airflow.

Individual Venting

Best practices for single dryer exhaust.

Manifold Venting

Guidelines for connecting multiple dryers to a common duct.

Gas Requirements

Gas Supply Pipe Sizing and Looping

How to size and install gas supply piping.

High Altitude Burner Orifice Sizing

Adjustments for burner orifices at high altitudes.

Electrical Requirements

Grounding Instructions

Procedures for proper electrical grounding and safety.

To Connect Electrical Service To The Tumble Dryer

Step-by-step guide for electrical hookup.

Jumper Configuration Instructions

How to configure voltage jumpers for different power sources.

Ferrite Ring Installation

Instructions for installing a ferrite ring for electrical noise reduction.

Electrical Specifications

Technical data on wiring, breakers, and voltage for various models.

Steam Requirements

Piping Recommendations

Guidelines for steam supply and return piping.

Installing Steam Trap and Making Condensate Return Connections

Procedure for setting up steam traps and return lines.

Thermal Oil Prep

Information for models using thermal oil heating systems.

Single Drop Timer

Power-Up Mode

Describes the dryer's state when power is applied.

Ready Mode

The state where the dryer awaits a coin or selection.

Start Mode

The state after a coin is inserted, waiting for the start button.

Run Mode

The state when the dryer is actively running a cycle.

Setting Dry Time Dipswitches

How to adjust drying times using control dipswitches.

Resetting Cycle Time to Zero

Procedure to reset the cycle timer to factory defaults.

Dipswitch Settings

Tables detailing dipswitch configurations for time settings.

Operating Instructions

Emergency Stop Button On CE Models

How to use the emergency stop button on CE models.

Dual Digital Timer Control

Instructions for operating the Dual Digital Timer control.

Electronic OPL Micro Control

Operation guide for the Electronic OPL Micro control.

Reversing Operation

Explanation of how the cylinder reversal feature works.

Single Drop Control

Operating procedures for the Single Drop control.

Error Codes

Lists display codes, definitions, and corrective actions.

MDC Coin and Card Control

Operation of the MDC Coin and Card control system.

Quantum Control

Operation guide for the Quantum control system.

Galaxy 600 Control

Operation guide for the Galaxy 600 control system.

LED OPL Control

Operation of the LED OPL control system.

UniLinc Control

Operation guide for the UniLinc control system.

DX4 Coin Control

Operation of the DX4 Coin control system.

DX4 OPL Control

Operation of the DX4 OPL control system.

Diagnostic Microprocessor Control

General operation of the DMP control system.

DMP OPL Models

Description of the DMP OPL control panel.

DMP OPL Features

Details on DIP switch settings for DMP OPL models.

Programming

Instructions for programming DMP models.

Operational Check for the Board Diagnostics

How to perform operational checks on control boards.

Ignition Control Operation and Troubleshooting for Models Starting 3;11;13

Operation and troubleshooting for ignition controls.

Flame Probe Tests

Procedures for testing flame detection components.

Diagnostic LED (DGN LED);Error Codes

Explanation of diagnostic LED status and error codes.

Adjustments

Gas Burner Air Shutter

How to adjust the air shutter for proper flame.

Airflow Switch

Information on the airflow switch and its importance.

Loading Door Switch

How to adjust the door switch for proper operation.

Loading Door Catch

Adjustment procedure for the door catch tension.

Drive Belt

Instructions for adjusting drive belt tension for various models.

Maintenance

Daily

Routine daily checks and cleaning procedures.

Monthly

Tasks to perform on a monthly basis.

Quarterly

Tasks to perform on a quarterly basis.

Bi-Annually

Tasks to perform every six months.

Annually

Tasks to perform once a year.

Fire Suppression System Maintenance Test

Procedure for testing the fire suppression system.

Before You Call for Service

Removing Tumble Dryer from Service

Steps for safely disconnecting and removing the dryer.

Disposal of Unit

ALLIANCE HT075N Specifications

General IconGeneral
BrandALLIANCE
ModelHT075N
CategoryDryer
LanguageEnglish

Related product manuals