DIP FUNCTIONS (Dip Switch SW1)
DIP 1 : ON : LEAF DOOR FUNCTION ACTIVATED ( photocell stops movement in opening)
OFF: LEAF DOOR (P. L.) DISACTIVATED
DIP 2 : ON : ANTI-DRAGGING FUNCTION ACTIVATED (with low and/or hight photocell
obscured, the control does not grasp the opening order)
OFF : ANTI-DRAGGING DISACTIVATED
DIP 3 : ON : PRESSED BUTTON FUNCTION (look at the instructions next page)
OFF : PRESSED BUTTON DISACTIVATED : Automatic or Semiautomatic cycle
DIP 4 : ON : DYNAMIC FUNCTION ON BUTTOM : OPEN - BLOCK - CLOSE
OFF : DYNAMIC FUNCTION DISACTIVATED (Normal Cycle: Open - Close)
DIP 5 : ON : THE BLINKER BLINKS DURING ALL THE CYCLE
(il pulsante di blocco 5 e 6 di M1 - lo spegne)
OFF : THE BLINKER FIRST BLINK 4 SEC BEFORE CLOSING
(the button of block 5 and 6 of M1 - switches it off)
DIP 6 : ON : AUTO-TEST FUNCTION DW24B ACTIVATED
OFF : AUTO-TEST DW24B DISACTIVATED
DIP 7: ON : AUTO-TEST FUNCTION LOW PHOTOCELL ACTIVATED
OFF : AUTO-TEST LOW PHOTOCELL DISACTIVATED
DIP 8 : ON : AUTO-TEST FUNCTION HIGH PHOTOCELL ACTIVATED
OFF : AUTO-TEST HIGH PHOTOCELL DISACTIVATED
WARNING OF FAILURE AUTOTEST :
- If the low photocell does not work, the blinker advises with a blink of 2 seconds and the control
does not move.
- If the hight photocell does not work, the blinker advises with 2 blink of 2 seconds and the control
does not move.
- If the DW 24B does not work, the blinker advises with 3 blink of 2 seconds and the control
does not move.