Chapter 6 Troubleshooting
Condition Description Solution
Server is not shutting
down properly.
Server is not responding to a
normal shut down request.
Press and hold the Power button for at least 4 seconds.
Server Power button is
blinking red.
Server is not operating properly. The red blinking sequence is:
For other Power button indications, see
“Power Connection” on page 14
or
“Safe Mode Sequence” on page 15.
Blinks in
sequence
Description
1
Internal system error.*
2
Internal power supply error.*
3
Internal operating temperature exceeds
maximum recommended limits.
Check for proper ventilation and installation
environment.
4
The main processor did not boot properly.*
* Contact the Allworx Technical Support for further assistance.