Adjustment
Procedures
|
@
Output
Voltage
Adjustment
VTVM
(Output
Terminal:
No
load)
Unit
Under
Test
(1)
Set
the
DC
supply
voltage
to
14V.
(2)
Connect
a
VTVM
to
TP
3
and
TP
4.
(Figure
6)
(3)
Rotate
the
semi-fixed
variable
resistor
(VR102)
to
be
55.0V
DC
on
the
voltmeter.
@
Cut-Off
Circuit
Adjustment
(1)
Set
the
DC
supply
voltage
to
10.40V.
(2)
Connect
an
oscilloscope
and
a
mili-voltmeter
to
Range
at
30V
or
50V
Figure
6
TP
1
and
TP
2
(Figure
7)
(Read
this
voltage
value
to
be
at
0
dB
point.)
(3)
Rotate
the
semi-fixed
-variable
resistor
(VR101)
Oscilloscope
fully
counterclockwise.
Mili-voltmeter
(4)
Read
voltage
on
the
mili-voltmeter
and
its
reading
is
at
O
dB
point.
(Figure
7)
(5)
Rotate
the
VR101
clockwise
slowly
and
adjust
it
to
be
—1
dB
down
from
voltage
as
indicated
in
above
step
(4).
Adjustment
Location
Figure
7
Relay
P.C.Board
Bottom
View