Impact Sensor Adjustment
Remote Control Programming
1. The system must be disarmed. Press and hold the Valet/Disarm switch in
the ON position during the entire coding procedure.
2. While holding the Valet/Disarm switch in the ON position, switch
ignition on and off three times. The LED will blink rapidly.
3. Press the TX/PANIC button on the remote control that you wish to program.
The siren will chirp twice to verify receiving the new remote control code.
4. Release the Valet/Disarm switch.
NOTE - The SEC-8028 can learn up to four remote control identification codes. When a new remote is coded, the security system will bump-out the oldest
code if the system originally contained four remote control identification codes.
TX/
PANIC
EXT2/
EXT3
EXT1/
VALET
MODE
Rev. 1/28/00
SEC-8028
T
X
/
P
A
N
IC
E
X
T
2/
E
X
T
3
E
X
T
1
/
V
A
L
E
T
M
O
D
E
TX/
PANIC
EXT2/
EXT3
EXT1/
VALET
MODE
TX/
PANIC
EXT2/
EXT3
EXT1/
VALET
MODE
Within five seconds, press and imediatly release (DO NOT HOLD) the TX/Panic and
EXT-1/Valet buttons simultaneously. The status LED will illuminate once again. The system is
now in the Impact Sensor Sensitivity Adjustment mode for the pre-warn field.
Press and release the TX/Panic button to increase the pre-warn sensitivity. Press and release the
EXT-1/Valet button to decrease the pre-warn sensitivity. Each time the sensitivity is adjusted, the
siren will chirp once. When the maximum or minimum sensitivity is reached, the siren will chirp
twice. To test the pre-warn sensitivity level, strike the vehicle with a light impact. The status LED
will blink once to indicate that the pre-warn sensitivity level has been exceeded.
The system must be disarmed. Place the system into the Valet mode through the Valet/Disarm
switch. The status LED will illuminate for one second.
When the pre-warn sensitivity level is acceptable, press and release the TX/Panic and
EXT-1/Valet buttons simultaneously to adjust the final trigger sensitivity level. The siren will
chirp three (3) times to indicate that you are in the final trigger sensitivity adjustment mode.
When the sensitivity adjustment procedure is completed, press and release the TX/Panic and
the EXT-1/Valet buttons simultaneously. The status LED will blink twice and you will exit the
adjustment mode. The system has now returned to the disarmed state.
Press and release the TX/Panic button to increase the final-trigger sensitivity. Press and release the
EXT-1/Valet button to decrease the final-trigger sensitivity. Each time the sensitivity is adjusted, the
siren will chirp once. When the maximum or minimum sensitivity is reached, the siren will chirp
twice. To test the sensitivity level, strike the vehicle with enough impact in which you feel should
trigger the system into an alarming state. The LED will blink three times indicating that the final-
trigger sensitivity level is exceeded.
Press Valet for 1 second
LED will blink once
Siren chirps three times
Press TX and EXT1 to
enter prewarn adjust
Press TX
to increase
sensitivity
siren chirps
once
Press EXT1
to decrease
sensitivity
siren chirps
once
Press TX and EXT1 to
enter final trigger
adjustment
Siren chirps twice
at min or max
Press TX
to increase
sensitivity
siren chirps
once
Press EXT1
to decrease
sensitivity
siren chirps
once
Siren chirps twice
at minimum or
maximum settings
LED will ablink twice
Press TX and EXT1 to
exit adjustment mode
Press and hold Valet
Press TX button on new
remote
Siren chirps twice
Turn Ignition ON/OFF 3
times
LED blinks rapidly
Release valet
T
X
/
P
A
N
I
C
E
X
T
2
/
E
X
T
3
E
X
T
1
/
V
A
L
E
T
M
O
D
E
LED will blink once
TX/
PANIC
EXT2/
EXT3
EXT1/
VALET
MODE
TX/
PANIC
EXT2/
EXT3
EXT1/
VALET
MODE
T
X
/
P
A
N
I
C
E
X
T
2
/
E
X
T
3
E
X
T
1
/
V
A
L
E
T
M
O
D
E
Page 3
Installation Instructions (English)
2
1
1
1 2
3
4
ENTER VALET MODE
ENTER PROGRAMMING MODE
ADJUST PRE-WARN SETTING
ADVANCE TO FINAL-TRIGGER SETTING
ADJUST FINAL TRIGGER SETTING
EXIT PROGRAMMING