Alpine STi Series Gas Fireplaces
3
SAFETY INFORMATION
Listed: DIRECT VENT GAS FIREPLACE HEATER
Tested to: ANSI Z21.88 1998
Report No. 476-1808-00 (July 2000)
DO NOT REMOVE THIS LA-
Serial Number: STi-
NATURAL GAS : Series STi-NG
Model: STi-270 STi-310 STi-360
STi- 270 STi-310 STi-360
Orifice Size (DMS) 36 33 31
Minimum Input 18,000 21,000 22,000
Maximum Input 30,000 34,000 38,000
Altitude 2500-6500ft. ASL
Minimum supply pressure 5” WC
Manifold pressure high 3.5” WC
Manifold pressure low 1.2” WC
VENTING: Use Only Simpson Dura-Vent Termination Components. Use only Simpson vent cap #9080 on all
applications. This appliance must be installed in accordance with the manufacturer’s installation instructions and
with local codes, if any; if not, follow the current ANSI Z223.1 in the USA. Electrical supply 120VAC, .50 Amps,
60Hz. NOT FOR USE WITH SOLID FUEL. This vented gas fireplace is not to be used with air filters.
Alpine Gas Fire-
places
Lehi, Utah
Field Converted
Put Label Here
Clearances to Combustibles Unless Specified
Side Wall from glass frame A 10”
Ceiling from top of louver B 48”
Min. Mantel Clearance C 13”
Mantel Depth D 3
1/2”
Mantel Clearance C 18”
Max. Mantel Depth D 12”
Hearth Height E 0”
Hearth Depth F 16”
PROPANE : Series STi-LP
Model: STi-270 STi-310 STi-360
STi- 270 STi-310 STi-360
Orifice Size (DMS) 53 52 51
Minimum Input 21,000 24,000 26,000
Maximum Input 30,000 34,000 38,000
Altitude 2500-6500ft. ASL
Minimum supply pressure 11” WC
Manifold pressure high 10” WC
Manifold pressure low 6” WC