Technical Guide P12y/EN FT/D22
User Guide
MiCOM P125/P126/P127 Page 81/108
tIe>>> :65432
00010
Assigning third trip threshold for earth fault overcurrent
(tIe>>>) to the output relays; i.e. to output 3 (RL3).
Setting choice: 1 assigns the output relay; 0 no
assignment.
Ie_R>>> :65432
00010
Assigning third trip threshold for directional earth fault
overcurrent from the inverse trip zone (Ie_R>>>) to
the output relays; i.e. to output 3 (RL3).
Setting choice: 1 assigns the output relay; 0 no
assignment.
Pe/ :65432
IeCos> 00010
Assigning first earth wattmetric alarm threshold
(Pe/IeCos>) to the output relays; i.e. to output 3 (RL3).
Setting choice: 1 assigns the output relay; 0 no
assignment.
tPe/ :65432
IeCos> 00010
Assigning first earth wattmetric trip threshold
(tPe/IeCos>) to the output relays; i.e. to output 3 (RL3).
Setting choice: 1 assigns the output relay; 0 no
assignment.
Pe/ :65432
IeCos>> 00010
Assigning second earth wattmetric alarm threshold
(Pe/IeCos>>) to the output relays; i.e. to output 3
(RL3).
Setting choice: 1 assigns the output relay; 0 no
assignment.
tPe/ :65432
IeCos>> 00010
Assigning second earth wattmetric trip threshold
(tPe/IeCos>>) to the output relays; i.e. to output 3
(RL3).
Setting choice: 1 assigns the output relay; 0 no
assignment.
Ue>>>> :65432
00010
Assigning the alarm threshold for residual overvoltage
(Ue>>>>) to the output relays; i.e. to output 3 (RL3).
Setting choice: 1 assigns the output relay; 0 no
assignment.
tUe>>>> :65432
00010
Assigning trip threshold for residual overvoltage
(tUe>>>>) to the output relays; i.e. to output 3 (RL3).
Setting choice: 1 assigns the output relay; 0 no
assignment.
tAUX1 :65432
00010
Assigning delayed auxiliary input Aux 1 to the output
relays; i.e. to output 3 (RL3).
Setting choice: 1 assigns the output relay; 0 no
assignment.
t AUX2 :65432
00010
Assigning delayed auxiliary input Aux 2 to the output
relays; i.e. to output 3 (RL3).
Setting choice: 1 assigns the output relay; 0 no
assignment.