EasyManua.ls Logo

Altech BT300i - Capacity & COP Table

Altech BT300i
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
V1 JUIN 2010 ALTECH Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual
12
3.
Capacity & COP table
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
- 7 - 2 2 7 12 15 20 25 30 35 40 43
0. 50
1. 00
1. 50
2. 00
2. 50
3. 00
3. 50
4. 00
4. 50
5. 00
5. 50
Capa. ( W)
COP ( W/ W)
Ambient Temperature
Ambient temp. Capacity(W)
COP(W/W)
-7 1459 1.93
-2 1614 2.08
2 1740 2.36
7 2156 2.8
10 2419 3.15
15 2926 3.6
20 3125 3.86
25 3523 4.07
30 3983 4.46
35 4230 4.63
40 4450 4.86
43 4621 4.95
Remark:
Water inlet temp. 15℃℃ Water outlet temp. 45